Network Working Group J. Flick Request for Comments: 2266 Hewlett Packard Company Category: Standards Track January 1998 Definitions of Managed Objects for IEEE 802.12 Repeater Devices Status of this Memo This document specifies an Internet standards
  Network Working Group J. Flick
Request for Comments: 2266 Hewlett Packard Company
Category: Standards Track January 1998

Definitions of Managed Objects for IEEE 802.12 Repeater Devices

Status of this Memo

This document specifies an Internet standards track protocol for the
Internet community, and requests discussion and suggestions for
improvements. Please refer to the current edition of the "Internet
Official Protocol Standards" (STD 1) for the standardization state
and status of this protocol. Distribution of this memo is unlimited.

Copyright Notice

Copyright (C) The Internet Society (1998). All Rights Reserved.

Abstract

This memo defines a portion of the Management Information Base (MIB)
for use with network management protocols in TCP/IP-based internets.
In particular, it defines objects for managing network repeaters
based on IEEE 802.12.

Table of Contents

1. The SNMP Network Management Framework ...................... 2
1.1. Object Definitions ....................................... 2
2. Overview ................................................... 2
2.1. Repeater Management Model ................................ 3
2.2. MAC Addresses ............................................ 4
2.3. Master Mode and Slave Mode ............................... 4
2.4. IEEE 802.12 Training Frames .............................. 4
2.5. Structure of the MIB ..................................... 6
2.5.1. Basic Definitions ...................................... 7
2.5.2. Monitor Definitions .................................... 7
2.5.3. Address Tracking Definitions ........................... 7
2.6. Relationship to other MIBs ............................... 7
2.6.1. Relationship to MIB-II ................................. 7
2.6.1.1. Relationship to the 'system' group ................... 7
2.6.1.2. Relationship to the 'interfaces' group ............... 8
2.6.2. Relationship to the 802.3 Repeater MIB ................. 8

2.7. Mapping of IEEE 802.12 Managed Objects ................... 9
3. Definitions ................................................ 12
4. Acknowledgements ........................................... 53
5. References ................................................. 53
6. Security Considerations .................................... 54
7. Author's Address ........................................... 55
8. Full Copyright Statement ................................... 56

1. The SNMP Network Management Framework

The SNMP Network Management Framework consists of several components.
For the purpose of this specification, the applicable components of
the Framework are the SMI and related documents [2, 3, 4], which
define the mechanisms used for describing and naming objects for the
purpose of management.

The Framework permits new objects to be defined for the purpose of
experimentation and evaluation.

1.1. Object Definitions

Managed objects are accessed via a virtual information store, termed
the Management Information Base (MIB). Objects in the MIB are
defined using the subset of Abstract Syntax Notation One (ASN.1) [1]
defined in the SMI [2]. In particular, each object type is named by
an OBJECT IDENTIFIER, an administratively assigned name. The object
type together with an object instance serves to uniquely identify a
specific instantiation of the object. For human convenience, we
often use a textual string, termed the descriptor, to refer to the
object type.

2. Overview

Instances of these object types represent attributes of an IEEE
802.12 repeater, as defined by Section 12, "RMAC Protocol" in IEEE
Standard 802.12-1995 [6].

The definitions presented here are based on Section 13, "Layer
management functions and services", and Annex C, "GDMO Specifications
for Demand Priority Managed Objects" of IEEE Standard 802.12-1995
[6].

Implementors of these MIB objects should note that the IEEE document
explicitly describes (in the form of Pascal pseudocode) when, where,
and how various repeater attributes are measured. The IEEE document
also describes the effects of repeater actions that may be invoked by
manipulating instances of the MIB objects defined here.

The counters in this document are defined to be the same as those
counters in IEEE Standard 802.12-1995, with the intention that the
same instrumentation can be used to implement both the IEEE and IETF
management standards.

2.1. Repeater Management Model

The model used in the design of this MIB allows for a managed system
to contain one or more managed 802.12 repeaters, and one or more
managed 802.12 repeater ports.

A repeater port may be thought of as a source of traffic into a
repeater in the system. The vgRptrBasicPortTable contains entries
for each physical repeater port in the managed system. An
implementor may choose to separate these ports into "groups". For
example, a group may be used to represent a field-replaceable unit,
so that the port numbering may match the numbering in the hardware
implementation. Note that this group mapping is recommended but
optional. An implementor may choose to put all of the system's ports
into a single group, or to divide the ports into groups that do not
match physical divisions. Each group within the system is uniquely
identified by a group number. Each port within a system is uniquely
identified by a combination of group number and port number. The
method of numbering groups and ports is implementation-specific.
Both groups and ports may be sparsely numbered.

In addition to the externally visible ports, some implementations may
have internal ports that are not obvious to the end-user but are
nevertheless sources of traffic into the repeater system. Examples
include internal management ports, through which an agent
communicates, and ports connecting to a backplane internal to the
implementation. It is the decision of the implementor to select the
appropriate group(s) in which to place internal ports.

Managed repeaters in the system are represented by entries in the
vgRptrInfoTable. There may be multiple repeaters in the managed
system. They are uniquely identified by a repeater number. The
method of numbering repeaters is implementation-specific. Each port
will either be associated with one of the repeaters, or isolated (a
so-called "trivial" repeater). The set of ports associated with a
single repeater will be in the same contention domain, and will be
participating in the same instance of the Demand Priority Access
Method protocol. The mapping of ports to repeaters may be static or
dynamic. A column in the vgRptrBasicPortTable,
vgRptrPortRptrInfoIndex, indicates the repeater that the port is
currently associated with. The method for assigning a port to a
repeater is implementation-specific.

2.2. MAC Addresses

All representations of MAC addresses in this MIB module are in
"canonical" order defined by 802.1a, i.e., as if it were transmitted
least significant bit first. This is true even if the repeater is
operating in token ring framing mode, which requires MAC addresses to
be transmitted most significant bit first.

2.3. Master Mode and Slave Mode

In an IEEE 802.12 network, "master" devices act as network
controllers to decide when to grant requesting end-nodes permission
to transmit. These master devices may be repeaters, or other active
controller devices such as switches.

Devices which do not act as network controllers, such as end-nodes or
passive switches, are considered to be operating in "slave" mode.

An 802.12 repeater always acts in "master" mode on its local ports,
which may connect to end nodes, switch or other device ports acting
in "slave" mode, or lower-level repeaters in a cascade. It acts in
"slave" mode on cascade ports, which may connect to an upper-level
repeater in a cascade, or to switch or other device ports operating
in "master" mode.

2.4. IEEE 802.12 Training Frames

Training frames are special MAC frames that are used only during link
initialization. Training frames are initially constructed by the
device at the "lower" end of a link, which is the slave mode device
for the link. The training frame format is as follows:

+----+----+------------+--------------+----------+-----+
| DA | SA | Req Config | Allow Config | Data | FCS |
+----+----+------------+--------------+----------+-----+

DA = destination address (six octets)
SA = source address (six octets)
Req Config = requested configuration (2 octets)
Allow Config = allowed configuration (2 octets)
Data = data (594 to 675 octets)
FCS = frame check sequence (4 octets)

Training frames are always sent with a null destination address. To
pass training, an end node must use its source address in the source
address field of the training frame. A repeater may use a non-null
source address if it has one, or it may use a null source address.

The requested configuration field allows the slave mode device to
inform the master mode device about itself and to request
configuration options. The training response frame from the master
mode device contains the slave mode device's requested configuration
from the training request frame. The currently defined format of the
requested configuration field as defined in the IEEE Standard
802.12-1995 standard is shown below. Please refer to the most
current version of the IEEE document for a more up to date
description of this field. In particular, the reserved bits may be
used in later versions of the standard.

First Octet: Second Octet:

7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
+-+-+-+-+-+-+-+-+ +-+-+-+-+-+-+-+-+
|v|v|v|r|r|r|r|r| |r|r|r|F|F|P|P|R|
+-+-+-+-+-+-+-+-+ +-+-+-+-+-+-+-+-+

vvv: The version of the 802.12 training protocol with which
the training initiator is compliant. The current version
is 100. Note that because of the different bit ordering
used in IEEE and IETF documents, this value corresponds
to version 1.
r: Reserved bits (set to zero)
FF: 00 = frameType88023
01 = frameType88025
10 = reserved
11 = frameTypeEither
PP: 00 = singleAddressMode
01 = promiscuousMode
10 = reserved
11 = reserved
R: 0 = the training initiator is an end node
1 = the training initiator is a repeater

The allowed configuration field allows the master mode device to
respond with the allowed configuration. The slave mode device sets
the contents of this field to all zero bits. The master mode device
sets the allowed configuration field as follows:

First Octet: Second Octet:

7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
+-+-+-+-+-+-+-+-+ +-+-+-+-+-+-+-+-+
|v|v|v|D|C|N|r|r| |r|r|r|F|F|P|P|R|
+-+-+-+-+-+-+-+-+ +-+-+-+-+-+-+-+-+

vvv: The version of the 802.12 training protocol with which
the training responder is compliant. The current version
is 100. Note that because of the different bit ordering
used in IEEE and IETF documents, this value corresponds
to version 1.
D: 0 = No duplicate address has been detected.
1 = Duplicate address has been detected.
C: 0 = The requested configuration is compatible with the
network and the attached port.
1 = The requested configuration is not compatible with
the network and/or the attached port. In this case,
the FF, PP, and R bits indicate a configuration that
would be allowed.
N: 0 = Access will be allowed, providing the configuration
is compatible (C = 0).
1 = Access is not granted because of security
restrictions.
r: Reserved bits (set to zero).
FF: 00 = frameType88023 will be used.
01 = frameType88025 will be used.
10 = reserved
11 = reserved
PP: 00 = singleAddressMode
01 = promiscuousMode
10 = reserved
11 = reserved
R: 0 = Requested access as an end node is allowed.
1 = Requested access as a repeater is allowed.

Again, note that the most recent version of the IEEE 802.12 standard
should be consulted for the most up to date definition of the
requested configuration and allowed configuration fields.

The data field contains between 594 and 675 octets and is filled in
by the training initiator. The first 55 octets may be used for
vendor specific protocol information. The remaining octets are all
zeros. The length of the training frame combined with the
requirement that 24 consecutive training frames be exchanged without
error to complete training ensures that marginal links will not
complete training.

2.5. Structure of the MIB

Objects in this MIB are arranged into OID subtrees, each of which
contains a set of related objects within a broad functional category.
These subtrees are intended for organizational convenience ONLY, and
have no relation to the conformance groups defined later in the
document.

2.5.1. Basic Definitions

The basic definitions include objects for managing the basic status
and control parameters for each repeater within the managed system,
for the port groups within the managed system, and for the individual
ports themselves.

2.5.2. Monitor Definitions

The monitor definitions include monitoring statistics for each
repeater within the system and for individual ports.

2.5.3. Address Tracking Definitions

This collection includes objects for tracking the MAC addresses of
the DTEs attached to the ports within the system.

Note that this MIB also includes by reference a collection of objects
from the 802.3 Repeater MIB which may be used for mapping the
topology of a network. These definitions are based on a technology
which has been patented by Hewlett-Packard Company (HP). HP has
granted rights to this technology to implementors of this MIB. See
[8] and [9] for details.

2.6. Relationship to other MIBs

2.6.1. Relationship to MIB-II

It is assumed that a repeater implementing this MIB will also
implement (at least) the 'system' group defined in MIB-II [5].

2.6.1.1. Relationship to the 'system' group

In MIB-II, the 'system' group is defined as being mandatory for all
systems such that each managed entity contains one instance of each
object in the 'system' group. Thus, those objects apply to the
entity even if the entity's sole functionality is management of
repeaters.

Note that all of the managed repeaters (i.e. entries in the
vgRptrInfoTable) will normally exist within a single naming scope.
Therefore, there will normally only be a single instance of each of
the objects in the system group for the entire managed repeater
system regardless of how many managed repeaters there are in the
system.

2.6.1.2. Relationship to the 'interfaces' group

In MIB-II, the 'interfaces' group is defined as being mandatory for
all systems and contains information on an entity's interfaces, where
each interface is thought of as being attached to a 'subnetwork'.
(Note that this term is not to be confused with 'subnet' which refers
to an addressing partitioning scheme used in the Internet suite of
protocols.)

This Repeater MIB uses the notion of ports on a repeater. The
concept of a MIB-II interface has NO specific relationship to a
repeater's port. Therefore, the 'interfaces' group applies only to
the one (or more) network interfaces on which the entity managing the
repeater sends and receives management protocol operations, and does
not apply to the repeater's ports.

This is consistent with the physical-layer nature of a repeater. An
802.12 repeater has an RMAC implementation, which acts as the
repeater end of the Demand Priority Access Method, but does not
contain a DTE MAC implementation, and does not pass packets up to
higher-level protocol entities for processing.

(When a network management entity is observing a repeater, it may
appear as though the repeater is passing packets to a higher-level
protocol entity. However, this is only a means of implementing
management, and this passing of management information is not part of
the repeater functionality.)

2.6.2. Relationship to the 802.3 Repeater MIB

An IEEE 802.12 repeater can be configured to operate in either
ethernet or token ring framing mode. This only affects the frame
format and address bit order of the frames on the wire. An 802.12
network does not use the media access protocol for either ethernet or
token ring. Instead, IEEE 802.12 defines its own media access
protocol, the Demand Priority Access Method (DPAM).

There is an existing standards-track MIB module for instrumenting
IEEE 802.3 repeaters [7]. That MIB module is designed to instrument
the operation of the repeater in a network implementing the 802.3
media access protocol. Therefore, much of that MIB does not apply to
802.12 repeaters.

However, the 802.3 Repeater MIB also contains a collection of objects
that may be used to map the topology of a network. These objects are
contained in a separable OBJECT-GROUP, are not 802.3-specific, and
are considered useful for 802.12 repeaters. In addition, the layer

management clause of the IEEE 802.12 specification includes similar
functionality. Therefore, vendors of agents for 802.12 repeaters are
encouraged to implement the snmpRptrGrpRptrAddrSearch OBJECT-GROUP
defined in the 802.3 Repeater MIB.

2.7. Mapping of IEEE 802.12 Managed Objects

IEEE 802.12 Managed Object Corresponding SNMP Object

oRepeater
.aCurrentFramingType vgRptrInfoCurrentFramingType
.aDesiredFramingType vgRptrInfoDesiredFramingType
.aFramingCapability vgRptrInfoFramingCapability
.aMACAddress vgRptrInfoMACAddress
.aRepeaterHealthState vgRptrInfoOperStatus
.aRepeaterID vgRptrInfoIndex
.aRepeaterSearchAddress SNMP-REPEATER-MIB -
rptrAddrSearchAddress
.aRepeaterSearchGroup SNMP-REPEATER-MIB -
rptrAddrSearchGroup
.aRepeaterSearchPort SNMP-REPEATER-MIB -
rptrAddrSearchPort
.aRepeaterSearchState SNMP-REPEATER-MIB -
rptrAddrSearchState
.aRMACVersion vgRptrInfoTrainingVersion
.acRepeaterSearchAddress SNMP-REPEATER-MIB -
rptrAddrSearchAddress
.acResetRepeater vgRptrInfoReset
.nRepeaterHealth vgRptrHealth
.nRepeaterReset vgRptrResetEvent

oGroup
.aGroupCablesBundled vgRptrGroupCablesBundled
.aGroupID vgRptrGroupIndex
.aGroupPortCapacity vgRptrGroupPortCapacity

oPort
.aAllowableTrainingType vgRptrPortAllowedTrainType
.aBroadcastFramesReceived vgRptrPortBroadcastFrames
.aCentralMgmtDetectedDupAddr vgRptrMgrDetectedDupAddress
.aDataErrorFramesReceived vgRptrPortDataErrorFrames
.aHighPriorityFramesReceived vgRptrPortHighPriorityFrames
.aHighPriorityOctetsReceived vgRptrPortHCHighPriorityOctets, or
vgRptrPortHighPriorityOctets and
vgRptrPortHighPriOctetRollovers
.aIPMFramesReceived vgRptrPortIPMFrames
.aLastTrainedAddress vgRptrAddrLastTrainedAddress
.aLastTrainingConfig vgRptrPortLastTrainConfig

.aLocalRptrDetectedDupAddr vgRptrRptrDetectedDupAddress
.aMulticastFramesReceived vgRptrPortMulticastFrames
.aNormalPriorityFramesReceived vgRptrPortNormPriorityFrames
.aNormalPriorityOctetsReceived vgRptrPortHCNormPriorityOctets, or
vgRptrPortNormPriorityOctets and
vgRptrPortNormPriOctetRollovers
.aNullAddressedFramesReceived vgRptrPortNullAddressedFrames
.aOctetsInUnreadableFramesRcvd vgRptrPortHCUnreadableOctets, or
vgRptrPortUnreadableOctets and
vgRptrPortUnreadOctetRollovers
.aOversizeFramesReceived vgRptrPortOversizeFrames
.aPortAdministrativeState vgRptrPortAdminStatus
.aPortID vgRptrPortIndex
.aPortStatus vgRptrPortOperStatus
.aPortType vgRptrPortType
.aPriorityEnable vgRptrPortPriorityEnable
.aPriorityPromotions vgRptrPortPriorityPromotions
.aReadableFramesReceived vgRptrPortReadableFrames
.aReadableOctetsReceived vgRptrPortHCReadableOctets, or
vgRptrPortReadableOctets and
vgRptrPortReadOctetRollovers
.aSupportedCascadeMode vgRptrPortSupportedCascadeMode
.aSupportedPromiscMode vgRptrPortSupportedPromiscMode
.aTrainedAddressChanges vgRptrAddrTrainedAddressChanges
.aTrainingResult vgRptrPortTrainingResult
.aTransitionsIntoTraining vgRptrPortTransitionToTrainings
.acPortAdministrativeControl vgRptrPortAdminStatus

The following IEEE 802.12 managed objects have not been included in
the 802.12 Repeater MIB for the indicated reasons.

IEEE 802.12 Managed Object Disposition

oRepeater
.aGroupMap Can be determined by GetNext sweep
of vgRptrBasicGroupTable

.aRepeaterGroupCapacity Meaning is unclear in many
repeater implementations. For
example, some cards may have
daughter cards which make group
capacity change depending on the
cards installed. Meaning is also
unclear in a stackable
implementation. Also, since
groups are not required to be
numbered from 1..capacity, but may
be computed algorithmically or

related to Entity MIB indices,
this object was not considered
useful.

.aRepeaterHealthData Since the data is implementation
specific and non-interoperable,
it was not considered useful.

.aRepeaterHealthText Implementation experience with
similar object in 802.3 Rptr MIB
indicated it was not useful.

.acExecuteNonDisruptiveSelfTest Implementation experience with
similar object in 802.3 Rptr MIB
indicated it was not useful.

.nGroupMapChange Since aGroupMap was not included,
a notification of a change in that
object was not needed.

oGroup
.aPortMap Can be determined by GetNext sweep
of vgRptrBasicPortTable
.nPortMapChange Since aPortMap was not included,
a notification of a change in that
object was not needed.

oPort
.aMediaType This object is a function of the
Physical Media Dependent (PMD)
layer, which is defined
differently for each type of
network. For an 802.3 network,
.aMediaType corresponds to the PMD
definitions in the 802.3 MAU MIB.
For management of an 802.12
network, mapping of this object is
deferred to future work on an
802.12 PMD MIB which will include
both repeater and interface PMD
information and redundant link
support.

3. Definitions

DOT12-RPTR-MIB DEFINITIONS ::= BEGIN

IMPORTS
mib-2, Integer32, Counter32, Counter64,
OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
MacAddress, TruthValue, TimeStamp
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF;

vgRptrMIB MODULE-IDENTITY
LAST-UPDATED "9705192256Z" -- May 19, 1997
ORGANIZATION "IETF 100VG-AnyLAN Working Group"
CONTACT-INFO
"WG E-mail: vgmib@hprnd.rose.hp.com

Chair: Jeff Johnson
Postal: RedBack Networks
2570 North First Street, Suite 410
San Jose, CA 95131
Tel: +1 408 571 2699
Fax: +1 408 571 2698
E-mail: jeff@redbacknetworks.com

Editor: John Flick
Postal: Hewlett Packard Company
8000 Foothills Blvd. M/S 5556
Roseville, CA 95747-5556
Tel: +1 916 785 4018
Fax: +1 916 785 3583
E-mail: johnf@hprnd.rose.hp.com"
DESCRIPTION
"This MIB module describes objects for managing
IEEE 802.12 repeaters."
::= { mib-2 53 }

vgRptrObjects OBJECT IDENTIFIER ::= { vgRptrMIB 1 }
vgRptrBasic OBJECT IDENTIFIER ::= { vgRptrObjects 1 }
vgRptrBasicRptr OBJECT IDENTIFIER ::= { vgRptrBasic 1 }

vgRptrInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF VgRptrInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION

"A table of information about each 802.12 repeater
in the managed system."
::= { vgRptrBasicRptr 1 }

vgRptrInfoEntry OBJECT-TYPE
SYNTAX VgRptrInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table, containing information
about a single repeater."
INDEX { vgRptrInfoIndex }
::= { vgRptrInfoTable 1 }

VgRptrInfoEntry ::=
SEQUENCE {
vgRptrInfoIndex Integer32,
vgRptrInfoMACAddress MacAddress,
vgRptrInfoCurrentFramingType INTEGER,
vgRptrInfoDesiredFramingType INTEGER,
vgRptrInfoFramingCapability INTEGER,
vgRptrInfoTrainingVersion INTEGER,
vgRptrInfoOperStatus INTEGER,
vgRptrInfoReset INTEGER,
vgRptrInfoLastChange TimeStamp
}

vgRptrInfoIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique identifier for the repeater for which
this entry contains information. The numbering
scheme for repeaters is implementation specific."
REFERENCE
"IEEE Standard 802.12-1995, 13.2.4.2.1,
aRepeaterID."
::= { vgRptrInfoEntry 1 }

vgRptrInfoMACAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MAC address used by the repeater when it
initiates training on the uplink port. Repeaters
are allowed to train with an assigned MAC address

or a null (all zeroes) MAC address."
REFERENCE
"IEEE Standard 802.12-1995, 13.2.4.2.1,
aMACAddress."
::= { vgRptrInfoEntry 2 }

vgRptrInfoCurrentFramingType OBJECT-TYPE
SYNTAX INTEGER {
frameType88023(1),
frameType88025(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of framing (802.3 or 802.5) currently
in use by the repeater."
REFERENCE
"IEEE Standard 802.12-1995, 13.2.4.2.1,
aCurrentFramingType."
::= { vgRptrInfoEntry 3 }

vgRptrInfoDesiredFramingType OBJECT-TYPE
SYNTAX INTEGER {
frameType88023(1),
frameType88025(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of framing which will be used by the
repeater after the next time it is reset.

The value of this object should be preserved
across repeater resets and power failures."
REFERENCE
"IEEE Standard 802.12-1995, 13.2.4.2.1,
aDesiredFramingType."
::= { vgRptrInfoEntry 4 }

vgRptrInfoFramingCapability OBJECT-TYPE
SYNTAX INTEGER {
frameType88023(1),
frameType88025(2),
frameTypeEither(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION

"The type of framing this repeater is capable of
supporting."
REFERENCE
"IEEE Standard 802.12-1995, 13.2.4.2.1,
aFramingCapability."
::= { vgRptrInfoEntry 5 }

vgRptrInfoTrainingVersion OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest version bits (vvv bits) supported by
the repeater during training."
REFERENCE
"IEEE Standard 802.12-1995, 13.2.4.2.1,
aRMACVersion."
::= { vgRptrInfoEntry 6 }

vgRptrInfoOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ok(2),
generalFailure(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vgRptrInfoOperStatus object indicates the
operational state of the repeater."
REFERENCE
"IEEE Standard 802.12-1995, 13.2.4.2.1,
aRepeaterHealthState."
::= { vgRptrInfoEntry 7 }

vgRptrInfoReset OBJECT-TYPE
SYNTAX INTEGER {
noReset(1),
reset(2)
}

MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to reset(2) causes the
repeater to transition to its initial state as
specified in clause 12 [IEEE Std 802.12].

Setting this object to noReset(1) has no effect.
The agent will always return the value noReset(1)
when this object is read.

After receiving a request to set this variable to
reset(2), the agent is allowed to delay the reset
for a short period. For example, the implementor
may choose to delay the reset long enough to
allow the SNMP response to be transmitted. In
any event, the SNMP response must be transmitted.

This action does not reset the management
counters defined in this document nor does it
affect the vgRptrPortAdminStatus parameters.
Included in this action is the execution of a
disruptive Self-Test with the following
characteristics:

1) The nature of the tests is not specified.
2) The test resets the repeater but without
affecting configurable management
information about the repeater.
3) Packets received during the test may or
may not be transferred.
4) The test does not interfere with
management functions.

After performing this self-test, the agent will
update the repeater health information (including
vgRptrInfoOperStatus), and send a
vgRptrResetEvent."
REFERENCE
"IEEE Standard 802.12-1995, 13.2.4.2.2,
acResetRepeater."
::= { vgRptrInfoEntry 8 }

vgRptrInfoLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when any of the following
conditions occurred:

1) agent cold- or warm-started;
2) this instance of repeater was created
(such as when a device or module was
added to the system);

3) a change in the value of
vgRptrInfoOperStatus;
4) ports were added or removed as members of
the repeater; or
5) any of the counters associated with this
repeater had a discontinuity."
::= { vgRptrInfoEntry 9 }

vgRptrBasicGroup OBJECT IDENTIFIER ::= { vgRptrBasic 2 }

vgRptrBasicGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF VgRptrBasicGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information about groups of
ports."
::= { vgRptrBasicGroup 1 }

vgRptrBasicGroupEntry OBJECT-TYPE
SYNTAX VgRptrBasicGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the vgRptrBasicGroupTable, containing
information about a single group of ports."
INDEX { vgRptrGroupIndex }
::= { vgRptrBasicGroupTable 1 }

VgRptrBasicGroupEntry ::=
SEQUENCE {
vgRptrGroupIndex Integer32,
vgRptrGroupObjectID OBJECT IDENTIFIER,
vgRptrGroupOperStatus INTEGER,
vgRptrGroupPortCapacity Integer32,
vgRptrGroupCablesBundled INTEGER
}

vgRptrGroupIndex OBJECT-TYPE
SYNTAX Integer32 (1..2146483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object identifies the group within the
system for which this entry contains information.
The numbering scheme for groups is implementation
specific."
REFERENCE

"IEEE Standard 802.12-1995, 13.2.4.4.1,
aGroupID."
::= { vgRptrBasicGroupEntry 1 }

vgRptrGroupObjectID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vendor's authoritative identification of the
group. This value may be allocated within the
SMI enterprises subtree (1.3.6.1.4.1) and
provides a straight-forward and unambiguous means
for determining what kind of group is being
managed.

For example, this object could take the value
1.3.6.1.4.1.4242.1.2.14 if vendor 'Flintstones,
Inc.' was assigned the subtree 1.3.6.1.4.1.4242,
and had assigned the identifier
1.3.6.1.4.1.4242.1.2.14 to its 'Wilma Flintstone
6-Port Plug-in Module.'"
::= { vgRptrBasicGroupEntry 2 }

vgRptrGroupOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
operational(2),
malfunctioning(3),
notPresent(4),
underTest(5),
resetInProgress(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An object that indicates the operational status
of the group.

A status of notPresent(4) indicates that the
group is temporarily or permanently physically
and/or logically not a part of the system. It
is an implementation-specific matter as to
whether the agent effectively removes notPresent
entries from the table.

A status of operational(2) indicates that the
group is functioning, and a status of

malfunctioning(3) indicates that the group is
malfunctioning in some way."
::= { vgRptrBasicGroupEntry 3 }

vgRptrGroupPortCapacity OBJECT-TYPE
SYNTAX Integer32 (1..2146483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vgRptrGroupPortCapacity is the number of
ports that can be contained within the group.
Valid range is 1-2147483647. Within each group,
the ports are uniquely numbered in the range from
1 to vgRptrGroupPortCapacity.

Some ports may not be present in the system, in
which case the actual number of ports present will
be less than the value of vgRptrGroupPortCapacity.
The number of ports present is never greater than
the value of vgRptrGroupPortCapacity.

Note: In practice, this will generally be the
number of ports on a module, card, or board, and
the port numbers will correspond to numbers marked
on the physical embodiment."
REFERENCE
"IEEE Standard 802.12-1995, 13.2.4.4.1,
aGroupPortCapacity."
::= { vgRptrBasicGroupEntry 4 }

vgRptrGroupCablesBundled OBJECT-TYPE
SYNTAX INTEGER {
someCablesBundled(1),
noCablesBundled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to indicate whether there are
any four-pair UTP links connected to this group
that are contained in a cable bundle with multiple
four-pair groups (e.g. a 25-pair bundle). Bundled
cable may only be used for repeater-to-end node
links where the end node is not in promiscuous
mode.

When a broadcast or multicast packet is received
from a port on this group that is not a

promiscuous or cascaded port, the packet will be
buffered completely before being repeated if
this object is set to 'someCablesBundled(1)'.
When this object is equal to 'noCablesBundled(2)',
all packets received from ports on this group will
be repeated as the frame is being received.

Note that the value 'someCablesBundled(1)' will
work in the vast majority of all installations,
regardless of whether or not any cables are
physically in a bundle, since packets received
from promiscuous and cascaded ports automatically
avoid the store and forward. The main situation
in which 'noCablesBundled(2)' is beneficial is
when there is a large amount of multicast traffic
and the cables are not in a bundle.

The value of this object should be preserved
across repeater resets and power failures."
REFERENCE
"IEEE Standard 802.12-1995, 13.2.4.4.1,
aGroupCablesBundled."
::= { vgRptrBasicGroupEntry 5 }

vgRptrBasicPort OBJECT IDENTIFIER ::= { vgRptrBasic 3 }

vgRptrBasicPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF VgRptrBasicPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing configuration and status
information about 802.12 repeater ports in the
system. The number of entries is independent of
the number of repeaters in the managed system."
::= { vgRptrBasicPort 1 }

vgRptrBasicPortEntry OBJECT-TYPE
SYNTAX VgRptrBasicPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the vgRptrBasicPortTable, containing
information about a single port."
INDEX { vgRptrGroupIndex, vgRptrPortIndex }
::= { vgRptrBasicPortTable 1 }

VgRptrBasicPortEntry ::=

SEQUENCE {
vgRptrPortIndex Integer32,
vgRptrPortType INTEGER,
vgRptrPortAdminStatus INTEGER,
vgRptrPortOperStatus INTEGER,
vgRptrPortSupportedPromiscMode INTEGER,
vgRptrPortSupportedCascadeMode INTEGER,
vgRptrPortAllowedTrainType INTEGER,
vgRptrPortLastTrainConfig OCTET STRING,
vgRptrPortTrainingResult OCTET STRING,
vgRptrPortPriorityEnable TruthValue,
vgRptrPortRptrInfoIndex Integer32
}

vgRptrPortIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object identifies the port within the group
for which this entry contains information. This
identifies the port independently from the
repeater it may be attached to. The numbering
scheme for ports is implementation specific;
however, this value can never be greater than
vgRptrGroupPortCapacity for the associated group."
REFERENCE
"IEEE Standard 802.12-1995, 13.2.4.5.1,
aPortID."
::= { vgRptrBasicPortEntry 1 }

vgRptrPortType OBJECT-TYPE
SYNTAX INTEGER {
cascadeExternal(1),
cascadeInternal(2),
localExternal(3),
localInternal(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Describes the type of port. One of the
following:

cascadeExternal - Port is an uplink with
physical connections which
are externally visible
cascadeInternal - Port is an uplink with

physical connections which
are not externally visible,
such as a connection to an
internal backplane in a
chassis
localExternal - Port is a downlink or local
port with externally
visible connections
localInternal - Port is a downlink or local
port with connections which
are not externally visible,
such as a connection to an
internal agent

'internal' is used to identify ports which place
traffic into the repeater, but do not have any
external connections. Note that both DTE and
cascaded repeater downlinks are considered
'local' ports."
REFERENCE
"IEEE Standard 802.12-1995, 13.2.4.5.1,
aPortType."
::= { vgRptrBasicPortEntry 2 }

vgRptrPortAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port enable/disable function. Enabling a
disabled port will cause training to be
initiated by the training initiator (the slave
mode device) on the link. Setting this object to
disabled(2) disables the port.

A disabled port neither transmits nor receives.
Once disabled, a port must be explicitly enabled
to restore operation. A port which is disabled
when power is lost or when a reset is exerted
shall remain disabled when normal operation
resumes.

The value of this object should be preserved
across repeater resets and power failures."
REFERENCE

"IEEE Standard 802.12-1995, 13.2.4.5.1,
aPortAdministrativeState."
::= { vgRptrBasicPortEntry 3 }

vgRptrPortOperStatus OBJECT-TYPE
SYNTAX INTEGER {
active(1),
inactive(2),
training(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status for the port as specified by the
PORT_META_STATE in the port process module of
clause 12 [IEEE Std 802.12].

During initialization or any link warning
conditions, vgRptrPortStatus will be
'inactive(2)'.

When Training_Up is received by the repeater on a
local port (or when Training_Down is received on
a cascade port), vgRptrPortStatus will change to
'training(3)' and vgRptrTrainingResult can be
monitored to see the detailed status regarding
training.

When 24 consecutive good FCS packets are exchanged
and the configuration bits are OK,
vgRptrPortStatus will change to 'active(1)'.

A disabled port shall have a port status of
'inactive(2)'."
REFERENCE
"IEEE Standard 802.12, 13.2.4.5.1,
aPortStatus."
::= { vgRptrBasicPortEntry 4 }

vgRptrPortSupportedPromiscMode OBJECT-TYPE
SYNTAX INTEGER {
singleModeOnly(1),
singleOrPromiscMode(2),
promiscModeOnly(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION

"This object describes whether the port hardware
is capable of supporting promiscuous mode, single
address mode (i.e., repeater filters unicasts not
addressed to the end station attached to this
port), or both. A port for which vgRptrPortType
is equal to 'cascadeInternal' or 'cascadeExternal'
will always have a value of 'promiscModeOnly' for
this object."
REFERENCE
"IEEE Standard 802.12-1995, 13.2.4.5.1,
aSupportedPromiscMode."
::= { vgRptrBasicPortEntry 5 }

vgRptrPortSupportedCascadeMode OBJECT-TYPE
SYNTAX INTEGER {
endNodesOnly(1),
endNodesOrRepeaters(2),
cascadePort(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object describes whether the port hardware
is capable of supporting cascaded repeaters, end
nodes, or both. A port for which vgRptrPortType
is equal to 'cascadeInternal' or
'cascadeExternal' will always have a value of
'cascadePort' for this object."
REFERENCE
"IEEE Standard 802.12-1995, 13.2.4.5.1,
aSupportedCascadeMode."
::= { vgRptrBasicPortEntry 6 }

vgRptrPortAllowedTrainType OBJECT-TYPE
SYNTAX INTEGER {
allowEndNodesOnly(1),
allowPromiscuousEndNodes(2),
allowEndNodesOrRepeaters(3),
allowAnything(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This security object is set by the network
manager to configure what type of device is
permitted to connect to the port. One of the
following values:

allowEndNodesOnly - only non-
promiscuous end
nodes permitted.
allowPromiscuousEndNodes - promiscuous or
non-promiscuous
end nodes
permitted
allowEndNodesOrRepeaters - repeaters or non-
promiscuous end
nodes permitted
allowAnything - repeaters,
promiscuous or
non-promiscuous
end nodes
permitted

For a port for which vgRptrPortType is equal to
'cascadeInternal' or 'cascadeExternal', the
corresponding instance of this object may not be
set to 'allowEndNodesOnly' or
'allowPromiscuousEndNodes'.

The agent must reject a SET of this object if the
value includes no capabilities that are
supported by this port's hardware, as defined by
the values of the corresponding instances of
vgRptrPortSupportedPromiscMode and
vgRptrPortSupportedCascadeMode.

Note that vgRptrPortSupportPromiscMode and
vgRptrPortSupportedCascadeMode represent what the
port hardware is capable of supporting.
vgRptrPortAllowedTrainType is used for setting an
administrative policy for a port. The actual set
of training configurations that will be allowed
to succeed on a port is the intersection of what
the hardware will support and what is
administratively allowed. The above requirement
on what values may be set to this object says that
the intersection of what is supported and what is
allowed must be non-empty. In other words, it
must not result in a situation in which nothing
would be allowed to train on that port. However,
a value can be set to this object as long as the
combination of this object and what is supported
by the hardware would still leave at least one
configuration that could successfully train on the
port.

The value of this object should be preserved
across repeater resets and power failures."
REFERENCE
"IEEE Standard 802.12-1995, 13.2.4.5.1,
aAllowableTrainingType."
::= { vgRptrBasicPortEntry 7 }

vgRptrPortLastTrainConfig OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(2))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is a 16 bit field. For local ports,
this object contains the requested configuration
field from the most recent error-free training
request frame sent by the device connected to
the port. For cascade ports, this object contains
the responder's allowed configuration field from
the most recent error-free training response frame
received in response to training initiated by this
repeater. The format of the current version of
this field is described in section 3.2. Please
refer to the most recent version of the IEEE
802.12 standard for the most up-to-date definition
of the format of this object."
REFERENCE
"IEEE Standard 802.12-1995, 13.2.4.5.1,
aLastTrainingConfig."
::= { vgRptrBasicPortEntry 8 }

vgRptrPortTrainingResult OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(3))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This 18 bit field is used to indicate the result
of training. It contains two bits which indicate
if error-free training frames have been received,
and it also contains the 16 bits of the allowed
configuration field from the most recent
error-free training response frame on the port.

First Octet: Second and Third Octets:
7 6 5 4 3 2 1 0
+-+-+-+-+-+-+-+-+-----------------------------+
|0|0|0|0|0|0|V|G| allowed configuration field |
+-+-+-+-+-+-+-+-+-----------------------------+

V: Valid: set when at least one error-free
training frame has been received.
Indicates the 16 training configuration
bits in vgRptrPortLastTrainConfig and
vgRptrPortTrainingResult contain valid
information. This bit is cleared when
vgRptrPortStatus transitions to the
'inactive' or 'training' state.
G: LinkGood: indicates the link hardware is
OK. Set if 24 consecutive error-free
training packets have been exchanged.
Cleared when a training packet with
errors is received, or when
vgRptrPortStatus transitions to the
'inactive' or 'training' state.

The format of the current version of the allowed
configuration field is described in section 3.2.
Please refer to the most recent version of the
IEEE 802.12 standard for the most up-to-date
definition of the format of this field.

If the port is in training, a management station
can examine this object to see if any training
packets have been passed successfully. If there
have been any good training packets, the Valid
bit will be set and the management station can
examine the allowed configuration field to see if
there is a duplicate address, configuration, or
security problem.

Note that on a repeater local port, this repeater
generates the training response bits, while on
a cascade port, the device at the upper end of
the link originated the training response bits."
REFERENCE
"IEEE Standard 802.12-1995, 13.2.4.5.1,
aTrainingResult."
::= { vgRptrBasicPortEntry 9 }
vgRptrPortPriorityEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A configuration flag used to determine whether
the repeater will service high priority requests
received on the port as high priority or normal
priority. When 'false', high priority requests

on this port will be serviced as normal priority.

The setting of this object has no effect on a
cascade port. Also note that the setting of this
object has no effect on a port connected to a
cascaded repeater. In both of these cases, this
setting is treated as always 'true'. The value
'false' only has an effect when the port is a
localInternal or localExternal port connected to
an end node.

The value of this object should be preserved
across repeater resets and power failures."
REFERENCE
"IEEE Standard 802.12-1995, 13.2.4.5.1,
aPriorityEnable."
::= { vgRptrBasicPortEntry 10 }

vgRptrPortRptrInfoIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the repeater that this
port is currently mapped to. The repeater
identified by a particular value of this object
is the same as that identified by the same value
of vgRptrInfoIndex. A value of zero indicates
that this port is not currently mapped to any
repeater."
::= { vgRptrBasicPortEntry 11 }

vgRptrMonitor OBJECT IDENTIFIER ::= { vgRptrObjects 2 }

vgRptrMonRepeater OBJECT IDENTIFIER ::= { vgRptrMonitor 1 }

vgRptrMonitorTable OBJECT-TYPE
SYNTAX SEQUENCE OF VgRptrMonitorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of performance and error statistics for
each repeater in the system. The instance of the
vgRptrInfoLastChange associated with a repeater
is used to indicate possible discontinuities of
the counters in this table that are associated
with the same repeater."

::= { vgRptrMonRepeater 1 }

vgRptrMonitorEntry OBJECT-TYPE
SYNTAX VgRptrMonitorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table, containing statistics
for a single repeater."
INDEX { vgRptrInfoIndex }
::= { vgRptrMonitorTable 1 }

VgRptrMonitorEntry ::=
SEQUENCE {
vgRptrMonTotalReadableFrames Counter32,
vgRptrMonTotalReadableOctets Counter32,
vgRptrMonReadableOctetRollovers Counter32,
vgRptrMonHCTotalReadableOctets Counter64,
vgRptrMonTotalErrors Counter32
}

vgRptrMonTotalReadableFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of good frames of valid frame
length that have been received on all ports in
this repeater. If an implementation cannot
obtain a count of frames as seen by the repeater
itself, this counter may be implemented as the
summation of the values of the
vgRptrPortReadableFrames counters for all of the
ports in this repeater.

This counter may experience a discontinuity when
the value of the corresponding instance of
vgRptrInfoLastChange changes."
::= { vgRptrMonitorEntry 1 }

vgRptrMonTotalReadableOctets OBJECT-TYPE
------分隔线----------------------------
顶一下
(0)
0%
踩一下
(0)
0%
------分隔线----------------------------
最新评论 查看所有评论
发表评论 查看所有评论
请自觉遵守互联网相关的政策法规,严禁发布色情、暴力、反动的言论。
评价:
表情:
用户名: 密码: 验证码:
推荐内容