RFC3512 - Configuring Networks and Devices with Simple Netwo(4)

时间:2005-02-17 来源: 作者: 点击:
entry is populated by the agent 'discovering' unconfigured rooms, the empty string is a valid value for this object." ::= { bldgHVACEntry 8 } bldgHVACStorageType OBJECT-TYPE SYNTAX StorageType MAX-AC
  
entry is populated by the agent 'discovering'
unconfigured rooms, the empty string is a valid
value for this object."
::= { bldgHVACEntry 8 }

bldgHVACStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The persistence of this row of the table in system storage,
as it pertains to permanence across system resets. A columnar
instance of this object with value 'permanent' need not allow
write-access to any of the columnar object instances in the
containing row."
::= { bldgHVACEntry 9 }

bldgHVACStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Controls and reflects the creation and activation status of
a row in this table.

No attempt to modify a row columnar object instance value in

the bldgHVACTable should be issued while the value of
bldgHVACStatus is active(1). Should an agent receive a SET
PDU attempting such a modification in this state, an
inconsistentValue error should be returned as a result of
the SET attempt."
::= { bldgHVACEntry 10 }
--
-- HVAC Configuration Template Table
--

bldgHVACCfgTemplateInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF BldgHVACCfgTemplateInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides unique string identification for
HVAC templates in a network. If it were necessary to
configure rooms to deliver a particular quality of climate
control with regard to cooling or heating, the index string
of a row in this table could be the template name.
The bldgHVACCfgCfgTemplateInfoDescription
contains a brief description of the template service objective
such as: provides summer cooling settings for executive
offices. The bldgHVACCfgTemplateInfo in the
bldgHVACCfgTemplateTable will contain the pointer to the
relevant row in this table if it is intended that items
that point to a row in the bldgHVACCfgTemplateInfoTable be
identifiable as being under template control though this
mechanism."

::= { bldgHVACObjects 2 }

bldgHVACCfgTemplateInfoEntry OBJECT-TYPE
SYNTAX BldgHVACCfgTemplateInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each row represents a particular template and
description. A given row instance can be created or
deleted by set operations upon its
bldgHVACCfgTemplateInfoStatus columnar object
instance."
INDEX { bldgHVACCfgTemplateInfoIndex }
::= { bldgHVACCfgTemplateInfoTable 1 }

BldgHVACCfgTemplateInfoEntry ::= SEQUENCE {
bldgHVACCfgTemplateInfoIndex Unsigned32,
bldgHVACCfgTemplateInfoID SnmpAdminString,

bldgHVACCfgTemplateInfoDescr SnmpAdminString,
bldgHVACCfgTemplateInfoOwner SnmpAdminString,
bldgHVACCfgTemplateInfoStatus RowStatus,
bldgHVACCfgTemplateInfoStorType StorageType
}

bldgHVACCfgTemplateInfoIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The unique index to a row in this table."
::= { bldgHVACCfgTemplateInfoEntry 1 }

bldgHVACCfgTemplateInfoID OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Textual identifier for this table row, and, consequently
the template. This should be a unique name within
an administrative domain for a particular template so that
all systems in a network that are under the same template
can have the same 'handle' (e.g., 'Executive Offices',
'Lobby Areas')."
::= { bldgHVACCfgTemplateInfoEntry 2 }

bldgHVACCfgTemplateInfoDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A general description of the template. One example might
be - Controls the cooling for offices on higher floors
during the summer."
::= { bldgHVACCfgTemplateInfoEntry 3 }

bldgHVACCfgTemplateInfoOwner OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The identity of the operator/system that last modified
this entry."
::= { bldgHVACCfgTemplateInfoEntry 4 }

bldgHVACCfgTemplateInfoStatus OBJECT-TYPE

SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The activation status of this row.

No attempt to modify a row columnar object instance value in
the bldgHVACCfgTemplateInfo Table should be issued while the
value of bldgHVACCfgTemplateInfoStatus is active(1).
Should an agent receive a SET PDU attempting such a modification
in this state, an inconsistentValue error should be returned as
a result of the SET attempt."
::= { bldgHVACCfgTemplateInfoEntry 5 }

bldgHVACCfgTemplateInfoStorType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The persistence of this row of the table in system storage,
as it pertains to permanence across system resets. A columnar
instance of this object with value 'permanent' need not allow
write-access to any of the columnar object instances in the
containing row."
::= { bldgHVACCfgTemplateInfoEntry 6 }

--
-- HVAC Configuration Template Table
--
bldgHVACCfgTemplateTable OBJECT-TYPE
SYNTAX SEQUENCE OF BldgHVACCfgTemplateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the templates, which
can be used to set defaults that will
be applied to specific offices. The application
of those values is accomplished by having a row
instance of the bldgHVACTable reference a row of
this table (by the value of the former's
bldgHVACCfgTemplate columnar instance). Identifying
information concerning a row instance of this table
can be found in the columnar data of the row instance
of the bldgHVACCfgTemplateInfoTable entry referenced
by the bldgHVACCfgTemplateInfo columnar object of
this table."
::= { bldgHVACObjects 3 }

bldgHVACCfgTemplateEntry OBJECT-TYPE
SYNTAX BldgHVACCfgTemplateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each row represents a single set of template parameters
that can be applied to selected instances - in this case
offices. These policies will be turned on and off by the
policy module through its scheduling facilities.

A given row instance can be created or
deleted by set operations upon its
bldgHVACCfgTemplateStatus columnar object instance."
INDEX { bldgHVACCfgTemplateIndex }
::= { bldgHVACCfgTemplateTable 1 }

BldgHVACCfgTemplateEntry ::= SEQUENCE {
bldgHVACCfgTemplateIndex Unsigned32,
bldgHVACCfgTemplateDesiredTemp Gauge32,
bldgHVACCfgTemplateCoolOrHeat BldgHvacOperation,
bldgHVACCfgTemplateInfo Unsigned32,
bldgHVACCfgTemplateOwner SnmpAdminString,
bldgHVACCfgTemplateStorage StorageType,
bldgHVACCfgTemplateStatus RowStatus
}

bldgHVACCfgTemplateIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value for each defined template in this
table. This value can be referenced as a row index
by any MIB module that needs access to this information.
The bldgHVACCfgTemplate will point to entries in this
table."
::= { bldgHVACCfgTemplateEntry 1 }

bldgHVACCfgTemplateDesiredTemp OBJECT-TYPE
SYNTAX Gauge32
UNITS "degrees in celsius"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the desired temperature setting. It might be
changed at different times of the day or based on
seasonal conditions. It is permitted to change this value
by first moving the row to an inactive state, making the

change and then reactivating the row."
::= { bldgHVACCfgTemplateEntry 2 }

bldgHVACCfgTemplateCoolOrHeat OBJECT-TYPE
SYNTAX BldgHvacOperation
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This controls the heating and cooling mechanism and is
set-able by building maintenance. It is permitted to
change this value by first moving the row to an inactive
state, making the change and then reactivating the row."
::= { bldgHVACCfgTemplateEntry 3 }

bldgHVACCfgTemplateInfo OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object points to a row in the
bldgHVACCfgTemplateInfoTable. This controls the
heating and cooling mechanism and is set-able by
building maintenance. It is permissible to change
this value by first moving the row to an inactive
state, making the change and then reactivating
the row. A value of zero means that this entry
is not associated with a named template found
in the bldgHVACCfgTemplateInfoTable."
::= { bldgHVACCfgTemplateEntry 4 }

bldgHVACCfgTemplateOwner OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The identity of the administrative entity
that created this row of the table."
::= { bldgHVACCfgTemplateEntry 5 }

bldgHVACCfgTemplateStorage OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The persistence of this row of the table across
system resets. A columnar instance of this object with
value 'permanent' need not allow write-access to any
of the columnar object instances in the containing row."

::= { bldgHVACCfgTemplateEntry 6 }

bldgHVACCfgTemplateStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The activation status of this row of the table.

No attempt to modify a row columnar object instance value in
the bldgHVACCfgTemplateTable should be issued while the
value of bldgHVACCfgTemplateStatus is active(1).
Should an agent receive a SET PDU attempting such a modification
in this state, an inconsistentValue error should be returned as
a result of the SET attempt."
::= { bldgHVACCfgTemplateEntry 7 }

--
-- Conformance Information
--

bldgCompliances OBJECT IDENTIFIER ::= { bldgConformance 1 }
bldgGroups OBJECT IDENTIFIER ::= { bldgConformance 2 }

-- Compliance Statements

bldgCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The requirements for conformance to the BLDG-HVAC-MIB. The
bldgHVACObjects group must be implemented to conform to the
BLDG-HVAC-MIB."
MODULE -- this module

GROUP bldgHVACObjectsGroup
DESCRIPTION
"The bldgHVACObjects is mandatory for all systems that
support HVAC systems."
::= { bldgCompliances 1 }

bldgHVACObjectsGroup OBJECT-GROUP
OBJECTS {
bldgHVACCfgTemplate,
bldgHVACFanSpeed, bldgHVACCurrentTemp,
bldgHVACCoolOrHeatMins, bldgHVACDiscontinuityTime,
bldgHVACOwner, bldgHVACStatus,
bldgHVACStorageType, bldgHVACCfgTemplateInfoID,
bldgHVACCfgTemplateInfoDescr, bldgHVACCfgTemplateInfoOwner,

bldgHVACCfgTemplateInfoStatus,
bldgHVACCfgTemplateInfoStorType,
bldgHVACCfgTemplateDesiredTemp,
bldgHVACCfgTemplateCoolOrHeat,
bldgHVACCfgTemplateInfo,
bldgHVACCfgTemplateOwner,bldgHVACCfgTemplateStorage,
bldgHVACCfgTemplateStatus
}
STATUS current
DESCRIPTION
"The bldgHVACObjects Group."
::= { bldgGroups 1 }

END

8.2. Notes on MIB Module with Template-based Data

The primary purpose of the example "HVAC" MIB module is to show how
to construct a single module that includes configuration, template,
counter and state information in a single module. If this were a
'real' module we would also have included definitions for
notifications for the configuration change operations as previously
described. We also would have included notifications for faults and
other counter threshold events.

Implementation and Instance Extensions:

Just as with networking technologies, vendors may wish to add
extensions that can distinguish their products from the competition.
If an HVAC vendor also wanted to support humidity control, they could
add that facility to their equipment and use AUGMENTS for the
bldgHVACTemplateTable with two objects, one that indicates the
desired humidity and the other, the actual. The
bldgHVACTemplateTable could also be extended using this same approach
so that HVAC policies could easily be extended to support this
vendor.

8.3. Examples of Usage of the MIB

The following two examples use two templates to configure the
temperature in executive offices and in conference rooms. The
"conference rooms" template is applied to all conference rooms (which
happen to be office 104 on each floor), and the "executive offices"
template is applied to executive offices.

If offices 24, 25, and 26 on the third floor are executive offices,
the values in the bldgHVACTable might be:

bldgHVACCfgTemplate.3.24 = 2
bldgHVACFanSpeed.3.24 = 2989
bldgHVACCurrentTemp.3.24 = 24
bldgHVACCoolOrHeatMins.3.24 = 123
bldgHVACDiscontinuityTime.3.24 = sysUpTime + 12h + 21m
bldgHVACOwner.3.24 = "policy engine"
bldgHVACStorageType.3.24 = nonVolatile(3)
bldgHVACStatus.3.24 = active(1)

bldgHVACCfgTemplate.3.25 = 2
bldgHVACFanSpeed.3.25 = 0
bldgHVACCurrentTemp.3.25 = 22
bldgHVACCoolOrHeatMins.3.25 = 298
bldgHVACDiscontinuityTime.3.25 = sysUpTime + 4h + 2m
bldgHVACOwner.3.25 = "policy engine"
bldgHVACStorageType.3.25 = nonVolatile(3)
bldgHVACStatus.3.25 = active(1)

bldgHVACCfgTemplate.3.26 = 2
bldgHVACFanSpeed.3.26 = 0
bldgHVACCurrentTemp.3.26 = 22
bldgHVACCoolOrHeatMins.3.26 = 982
bldgHVACOwner.3.26 = "policy engine"
bldgHVACStorageType.3.26 = nonVolatile(3)
bldgHVACStatus.3.26 = active(1)

The second entry in the bldgHVACCfgTemplateTable, to which all of the
above point, might have the following configuration:

bldgHVACCfgTemplateDesiredTemp.2 = 22
bldgHVACCfgTemplateCoolOrHeat.2 = cool(2)
bldgHVACCfgTemplateInfo.2 = 2
bldgHVACCfgTemplateOwner.2 = "Senior Executive assistant"
bldgHVACCfgTemplateStorage.2 = nonVolatile(3)
bldgHVACCfgTemplateStatus.2 = active(1)

and the associated template information ("executive offices") might
be:

bldgHVACCfgTemplateInfoID.2 = "executive offices"
bldgHVACCfgTemplateInfoDescr.2 = "Controls temperature for executive
offices"
bldgHVACCfgTemplateInfoOwner.2 = "Senior Executive assistant"
bldgHVACCfgTemplateInfoStorType.2 = nonVolatile(3)
bldgHVACCfgTemplateInfoStatus.2 = active(1)

The policy engine can now associate instances of executive offices
with the template called "executive offices" and apply the values in
the second entry of the bldgHVACCfgTemplateTable to each of the
instances of the executive offices. This will then attempt to set
the temperature in executive offices to 22 degrees celsius.

It is also possible that there may be an office configured for a
particular temperature, but without using a template. For example,
office 28 on the third floor might look like this:

bldgHVACCfgTemplate.3.28 = 3
bldgHVACFanSpeed.3.28 = 50
bldgHVACCurrentTemp.3.28 = 26
bldgHVACCoolOrHeatMins.3.28 = 0
bldgHVACDiscontinuityTime.3.28 = 0
bldgHVACOwner.3.28 = "Executive with poor circulation"
bldgHVACStorageType.3.28 = nonVolatile(3)
bldgHVACStatus.3.28 = active(1)

The entry in the bldgHVACCfgTemplateTable (to which
bldgHVACCfgTemplate.3.28 points) might instead look like:

bldgHVACCfgTemplateDesiredTemp.3 = 28
bldgHVACCfgTemplateCoolOrHeat.3 = cool(2)
bldgHVACCfgTemplateInfo.3 = 0.0
bldgHVACCfgTemplateOwner.3 = "Executive with poor circulation"
bldgHVACCfgTemplateStorage.3 = nonVolatile(3)
bldgHVACCfgTemplateStatus.3 = active(1)

Note that this entry does not point to a template.

If the executive's circulation improves so that the temperature
should be aligned with other executive offices, this is accomplished
by changing the value of bldgHVACCfgTemplate.3.28 from
bldgHVACCfgTemplateInfoID.3 to bldgHVACCfgTemplateInfoID.2 (shown
above).

Finally, there might be offices for which there is no configured
temperature but management applications can read the current
temperature, fan speed, and cooling or heating minutes from the
bldgHVACTable. In that case, the value of bldgHVACCfgTemplate will
be a zero index ("null"), as will the value of bldgHVACOwner.

bldgHVACCfgTemplate.4.2 = 0
bldgHVACFanSpeed.3.28 = 50
bldgHVACCurrentTemp.3.28 = 26
bldgHVACCoolOrHeatMins.3.28 = 0
bldgHVACDiscontinuityTime.3.28 = 0
bldgHVACOwner.3.28 = ""
bldgHVACStorageType.3.28 = nonVolatile(3)
bldgHVACStatus.3.28 = active(1)

As a second example, the conference rooms on several floors are
configured using the "conference rooms" template. When the values in
the bldgHVACTable pertaining to conference rooms are read, it might
look like:

bldgHVACCfgTemplate.12.104 = bldgHVACCfgTemplateDesiredTemp.1
bldgHVACFanSpeed.12.104 = 1423
bldgHVACCurrentTemp.12.104 = 21
bldgHVACCoolOrHeatMins.12.104 = 2193
bldgHVACDiscontinuityTime.12.104 = sysUpTime + 36h + 15m
bldgHVACOwner.12.104 = = "Bob the Conference Guy"
bldgHVACStorageType.12.104 = nonVolatile(3)
bldgHVACStatus.12.104 = active(1)

bldgHVACCfgTemplate.14.104 = bldgHVACCfgTemplateDesiredTemp.1
bldgHVACFanSpeed.14.104 = 1203
bldgHVACCurrentTemp.14.104 = 20
bldgHVACCoolOrHeatMins.14.104 = 293
bldgHVACDiscontinuityTime.14.104 = sysUpTime + 5h + 54m
bldgHVACOwner.14.104 = = "Bob the Conference Guy"
bldgHVACStorageType.14.104 = nonVolatile(3)
bldgHVACStatus.14.104 = active(1)

bldgHVACCfgTemplate.15.104 = bldgHVACCfgTemplateDesiredTemp.1
bldgHVACFanSpeed.15.104 = 12
bldgHVACCurrentTemp.15.104 = 19
bldgHVACCoolOrHeatMins.15.104 = 1123
bldgHVACDiscontinuityTime.15.103 = sysUpTime + 2d + 2h + 7m
bldgHVACOwner.15.104 = = "Bob the Conference Guy"
bldgHVACStorageType.15.104 = nonVolatile(3)
bldgHVACStatus.15.104 = active(1)

The desired temperature and whether to heat or cool is configured in
the first entry of the bldgHVACCfgTemplateTable, which tries to set
the temperature to 19 degrees celsius in conference rooms:

bldgHVACCfgTemplateDesiredTemp.1 = 19
bldgHVACCfgTemplateCoolOrHeat.1 = cool(2)
bldgHVACCfgTemplateInfo.1 = bldgHVACCfgTemplateInfoID.1
bldgHVACCfgTemplateOwner.1 = "Bob the Conference Guy"
bldgHVACCfgTemplateStorage.1 = nonVolatile(3)
bldgHVACCfgTemplateStatus.1 = active(1)

The associated template information would then have:

bldgHVACCfgTemplateInfoID.1 = "conference rooms"
bldgHVACCfgTemplateInfoDescr.1 = "Controls temperature in conference
rooms" bldgHVACCfgTemplateInfoOwner.1 = "Bob the Conference Guy"
bldgHVACCfgTemplateInfoStorType.1 = nonVolatile(3)
bldgHVACCfgTemplateInfoStatus.1 = active(1)

The policy system can then apply this template (cool to 19 degrees
Celsius) to its notion of all of the conference rooms in the
building.

9. Security Considerations

This document discusses practices and methods for using the SNMP for
management and distribution of configuration information for network
elements. Any effective use of the SNMP in this application must
concern itself with issues of authentication of the management
entities initiating configuration change and management, in addition
to the integrity of the configuration data itself. Other more subtle
considerations also exist.

To that end, the section of this document entitled "Deployment and
Security Issues" covers these security considerations to the extent
they affect the current practices described throughout this document.
In particular, in the subsection entitled "Secure Agent
Considerations", there is a recommendation for the usage of Version 3
of the SNMP, and its essential presumption as a foundation for other
practices described throughout. With the exception of a small number
of cases where a mention is made to the contrary to illustrate
techniques for coexistence with application entities dependent upon
earlier versions of the SNMP, that recommendation of usage of Version
3 of the SNMP is reiterated here.

10. Acknowledgments

This document was produced by the SNMPCONF Working Group. In
particular, the editors wish to thank:

Christopher Anderson
Andy Bierman
Greg Bruell
Dr Jeffrey Case
Chris Elliott
Joel Halpern
Pablo Halpern
Wes Hardaker
David Harrington
Harrie Hazewinkel
Thippanna Hongal
Bob Moore
David T. Perkins
Randy Presuhn
Dan Romascanu
Shawn Routhier
Steve Waldbusser
Bert Wijnen

11. Normative References

[1] Harrington, D., Presuhn, R. and B. Wijnen, "An Architecture for
Describing Simple Network Management Protocol (SNMP) Management
Frameworks", STD 62, RFC3411, December 2002.

[2] McCloghrie, K., Perkins, D. and J. Schoenwaelder, "Structure of
Management Information Version 2 (SMIv2)", STD 58, RFC2578,
April 1999.

[3] McCloghrie, K., Perkins, D. and J. Schoenwaelder, "Textual
Conventions for SMIv2", STD 58, RFC2579, April 1999.

[4] McCloghrie, K., Perkins, D. and J. Schoenwaelder, "Conformance
Statements for SMIv2", STD 58, RFC2580, April 1999.

[5] Presuhn, R. (Ed.), "Transport Mappings for the Simple Network
Management Protocol (SNMPv2)", STD 62, RFC3417, December 2002.

[6] Case, J., Harrington D., Presuhn R. and B. Wijnen, "Message
Processing and Dispatching for the Simple Network Management
Protocol (SNMP)", STD 62, RFC3412, December 2002.

[7] Blumenthal, U. and B. Wijnen, "User-based Security Model (USM)
for version 3 of the Simple Network Management Protocol
(SNMPv3)", STD 62, RFC3414, December 2002.

[8] Presuhn, R. (Ed.), "Version 2 of the Protocol Operations for the
Simple Network Management Protocol (SNMP)", STD 62, RFC3416,
December 2002.

[9] Levi, D., Meyer, P., and B. Stewart, "Simple Network Management
Protocol Applications", STD 62, RFC3413, December 2002.

[10] Wijnen, B., Presuhn, R. and K. McCloghrie, "View-based Access
Control Model (VACM) for the Simple Network Management Protocol
(SNMP)", STD 62, RFC3415, December 2002.

[11] Presuhn, R. (Ed.), "Management Information Base for the Simple
Network Management Protocol (SNMPv2)", STD 62, RFC3418,
December 2002.

[12] Case, J., Mundy, R., Partain, D. and B. Stewart, "Introduction
and Applicability Statements for Internet-Standard Management
Framework", RFC3410, December 2002.

[13] Daniele, M., Haberman, B., Routhier, S. and J. Schoenwaelder,
"Textual Conventions for Internet Network Addresses", RFC3291,
May 2002.

[14] McCloghrie, K. (Ed.), "SNMPv2 Management Information Base for
the Internet Protocol using SMIv2", RFC2011, November 1996.

12. Informative References

[15] Rose, M. and K. McCloghrie, "Structure and Identification of
Management Information for TCP/IP-based Internets", STD 16, RFC
1155, May 1990.

[16] Rose, M. and K. McCloghrie, "Concise MIB Definitions", STD 16,
RFC1212, March 1991.

[17] Rose, M., "A Convention for Defining Traps for use with the
SNMP", RFC1215, March 1991.

[18] Case, J., Fedor, M., Schoffstall, M. and J. Davin, "Simple
Network Management Protocol", STD 15, RFC1157, May 1990.

[19] Case, J., McCloghrie, K., Rose, M., and S. Waldbusser,
"Introduction to Community-based SNMPv2", RFC1901, January
1996.

[20] McCloghrie, K. and F. Kastenholz, "The Interfaces Group MIB",
RFC2863, June 2000.

[21] Brown, C. and F. Baker, "Management Information Base for Frame
Relay DTEs Using SMIv2", RFC2115, September 1997.

[22] Baker, F. (Ed.), "Requirements for IP Version 4 Routers", RFC
1812, June 1995.

[23] Hawkinson, J. and T. Bates, "Guidelines for Creation, Selection,
and Registration of an Autonomous System (AS)", BCP 6, RFC1930,
March 1996.

[24] Decker, E., Langille, P., Rijsinghani, A. and K. McCloghrie,
"Definitions of Managed Objects for Bridges", RFC1493, July
1993.

[25] Levi, D. and J. Schoenwaelder "Definitions of Managed Objects
for Scheduling Management Operations", RFC3231, January 2002.

[26] Bell, E., Smith, A., Langille, P., Rijsinghani, A. and K.
McCloghrie, "Definitions of Managed Objects for Bridges with
Traffic Classes, Multicast Filtering and Virtual LAN
Extensions", RFC2674, August 1999.

[27] Baker, F., "IP Forwarding Table MIB", RFC2096, January 1997.

[28] St. Johns, M. (Ed.), "Radio Frequency (RF) Interface Management
Information Base for MCNS/DOCSIS compliant RF interfaces", RFC
2670, August 1999.

[29] Baker, F. and R. Coltun, "OSPF Version 2 Management Information
Base", RFC1850, November 1995.

[30] Blake, S., Black, D., Carlson M., Davies, E., Wang, Z. and W.
Weiss, "An Architecture for Differentiated Services ", RFC2475,
December 1998.

[31] Willis, S., Burruss, J. and J. Chu (Ed.), "Definitions of
Managed Objects for the Fourth Version of the Border Gateway
Protocol (BGP-4) using SMIv2", RFC1657, July 1994.

[32] Waldbusser, S., "Remote Network Monitoring Management
Information Base", RFC2819, May 2000.

[33] McCloghrie, K. and G. Hanson, "The Inverted Stack Table
Extension to the Interfaces Group MIB", RFC2864, June 2000.

[34] McCloghrie, K. and A. Bierman, "Entity MIB (Version 2)", RFC
2737, December 1999.

[35] ITU-T,, Recommendation M.3010., PRINCIPLES FOR A
TELECOMMUNICATIONS MANAGEMENT NETWORK. February, 2000.

[36] Waldbusser, S., Saperia, J., and Hongal, T., "Policy Based
Management MIB", Work-in-progress.

[37] Heintz, L., "SNMP Row Operations Extensions", Work-in-progress.

[38] Zeltserman, D., "A Practical Guide to Snmpv3 and Network
Management", Prentice Hall, 1999.

[39] Noto, M., Spiegel, E. and K. Tesink, "Definitions of Textual
Conventions and OBJECT-IDENTITIES for ATM Management", RFC2514,
February 1999.

[40] Kassaveri, R., Editor, "Distributed Management Expression MIB",
RFC2982, October 2000.

[41] St. Johns, M., "DOCSIS Cable Device MIB Cable Device Management
Information Base for DOCSIS compliant Cable Modems and Cable
Modem Termination Systems", RFC2669, August 1999.

[42] Westerinen, A., Schnizlein, J., Strassner, J., Scherling, M.,
Quinn, B., Herzog, S., Huynh, A., Carlson, M., Perry, J. and S.
Waldbusser, "Terminology for Policy-Based Management", RFC3198,
November 2001.

[43] http://wwww.cisco.com/univercd/cc/td/product/software/ios113ed/
11ed_cr/secur_c/scprt/scacls.pdf.

[44] Waldbusser, S., "Remote Network Monitoring Management
Information Base Version 2 using SMIv2", RFC2021, January 1997.

13. Intellectual Property

The IETF takes no position regarding the validity or scope of any
intellectual property or other rights that might be claimed to
pertain to the implementation or use of the technology described in
this document or the extent to which any license under such rights
might or might not be available; neither does it represent that it
has made any effort to identify any such rights. Information on the
IETF's procedures with respect to rights in standards-track and
standards-related documentation can be found in BCP-11. Copies of
claims of rights made available for publication and any assurances of
licenses to be made available, or the result of an attempt made to

obtain a general license or permission for the use of such
proprietary rights by implementors or users of this specification can
be obtained from the IETF Secretariat.

The IETF invites any interested party to bring to its attention any
copyrights, patents or patent applications, or other proprietary
rights which may cover technology that may be required to practice
this standard. Please address the information to the IETF Executive
Director.

14. Editors' Addresses

Michael R. MacFaden
Riverstone Networks, Inc
5200 Great America Parkway
Santa Clara, CA 95054

EMail: mrm@riverstonenet.com

David Partain
Ericsson AB
P.O. Box 1248
SE-581 12 Linkoping
Sweden

EMail: David.Partain@ericsson.com

Jon Saperia
JDS Consulting
174 Chapman Street
Watertown, MA 02472

EMail: saperia@jdscons.com

Wayne F. Tackabury
Gold Wire Technology
411 Waverley Oaks Rd.
Waltham, MA 02452

EMail: wayne@goldwiretech.com

15. Full Copyright Statement

Copyright (C) The Internet Society (2003). All Rights Reserved.

This document and translations of it may be copied and furnished to
others, and derivative works that comment on or otherwise explain it
or assist in its implementation may be prepared, copied, published
and distributed, in whole or in part, without restriction of any
kind, provided that the above copyright notice and this paragraph are
included on all such copies and derivative works. However, this
document itself may not be modified in any way, such as by removing
the copyright notice or references to the Internet Society or other
Internet organizations, except as needed for the purpose of
developing Internet standards in which case the procedures for
copyrights defined in the Internet Standards process must be
followed, or as required to translate it into languages other than
English.

The limited permissions granted above are perpetual and will not be
revoked by the Internet Society or its successors or assigns.

This document and the information contained herein is provided on an
"AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION
HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Acknowledgement

Funding for the RFCEditor function is currently provided by the
Internet Society.