RFC 3592 - Definitions of Managed Objects for the Synchronou(5)

时间:2006-10-21 来源: 作者: 点击:
STATUScurrent DESCRIPTION "Anumberbetween1and96,whichidentifiesthe intervalforwhichthesetofstatisticsisavailable. Theintervalidentifiedby1isthemostrecently completed15minuteinterval, andtheintervalid
  
      STATUS  current
      DESCRIPTION
           "A number between 1 and 96, which identifies the
           interval for which the set of statistics is available.

           The interval identified by 1 is the most recently
           completed 15 minute interval,
           and the interval identified
           by N is the interval immediately preceding the
           one identified
           by N-1."
      ::= { sonetFarEndPathIntervalEntry 1 }

   sonetFarEndPathIntervalESs OBJECT-TYPE
      SYNTAX  PerfIntervalCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
           "The counter associated with the number of
           Far End Errored Seconds encountered
           by a SONET/SDH Path interface in a
           particular 15-minute interval
           in the past 24 hours."
      ::= { sonetFarEndPathIntervalEntry 2 }

   sonetFarEndPathIntervalSESs OBJECT-TYPE
      SYNTAX  PerfIntervalCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
           "The counter associated with the number of
           Far End Severely Errored Seconds
           encountered by a SONET/SDH Path interface
           in a particular 15-minute interval
           in the past 24 hours."
      ::= { sonetFarEndPathIntervalEntry 3 }

   sonetFarEndPathIntervalCVs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
            "The counter associated with the number of
            Far End Coding Violations reported via
            the far end block error count
            encountered by a
            SONET/SDH Path interface
            in a particular 15-minute interval
            in the past 24 hours."
       ::= { sonetFarEndPathIntervalEntry 4 }

   sonetFarEndPathIntervalUASs OBJECT-TYPE
      SYNTAX  PerfIntervalCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
          "The counter associated with the number of
          Far End Unavailable Seconds
          encountered by a
          SONET/SDH Path interface in
          a particular 15-minute interval
          in the past 24 hours."
      ::= { sonetFarEndPathIntervalEntry 5 }

   sonetFarEndPathIntervalValidData OBJECT-TYPE
       SYNTAX  TruthValue
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
          "This variable indicates if the data for this
           interval is valid."
       ::= { sonetFarEndPathIntervalEntry 6 }

   -- the SONET/SDH Virtual Tributary group

   -- this group consists of 2 tables:
   -- - the SONET/SDH VT Current Table
   -- - the SONET/SDH VT Interval Table

   -- Corresponding SDH signals for SONET VTs are
   -- as follows:

   -- A VT1.5 = TU11
   -- A VT2 = TU12
   -- A VT3 = none
   -- none  = TU3
   -- A VT6 = TU2

   -- the SONET/SDH VT Current Table

   -- The SONET/SDH VT current table
   -- contains various statistics
   -- being collected for the
   -- current 15 minute interval.

   sonetVTCurrentTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF SonetVTCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
        "The SONET/SDH VT Current table."
   ::= { sonetVT 1 }

   sonetVTCurrentEntry OBJECT-TYPE
       SYNTAX  SonetVTCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
        "An entry in the SONET/SDH VT Current table."
       INDEX   { ifIndex }
   ::= { sonetVTCurrentTable 1 }

   SonetVTCurrentEntry ::=
       SEQUENCE {
           sonetVTCurrentWidth      INTEGER,
           sonetVTCurrentStatus     Integer32,
           sonetVTCurrentESs        PerfCurrentCount,
           sonetVTCurrentSESs       PerfCurrentCount,
           sonetVTCurrentCVs        PerfCurrentCount,
           sonetVTCurrentUASs       PerfCurrentCount
       }

   sonetVTCurrentWidth OBJECT-TYPE
       SYNTAX  INTEGER {
               vtWidth15VC11(1),
               vtWidth2VC12(2),
               vtWidth3(3),
               vtWidth6VC2(4),
               vtWidth6c(5)
            }
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
       "A value that indicates the type of the SONET
        VT and SDH VC.  Assigned widths are
        VT1.5/VC11, VT2/VC12, VT3, VT6/VC2, and VT6c."
   ::= { sonetVTCurrentEntry 1 }

   sonetVTCurrentStatus OBJECT-TYPE
       SYNTAX  Integer32 (1..126)
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
         "This variable indicates the
         status of the interface.
         The sonetVTCurrentStatus
         is a bit map represented
         as a sum, therefore,
         it can represent multiple defects
         and failures
         simultaneously.
         The sonetVTNoDefect should be
         set if and only if
         no other flag is set.

         The various bit positions are:
            1   sonetVTNoDefect
            2   sonetVTLOP
            4   sonetVTPathAIS
            8   sonetVTPathRDI
           16   sonetVTPathRFI
           32   sonetVTUnequipped
           64   sonetVTSignalLabelMismatch"
   ::= { sonetVTCurrentEntry 2 }

   sonetVTCurrentESs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of Errored
        Seconds encountered by a SONET/SDH
        VT in the current 15 minute interval."
   ::= { sonetVTCurrentEntry 3 }

   sonetVTCurrentSESs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of
        Severely Errored Seconds
        encountered by a SONET/SDH VT in the current 15 minute
        interval."
   ::= { sonetVTCurrentEntry 4 }

   sonetVTCurrentCVs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of Coding
        Violations encountered by a
        SONET/SDH VT in the current 15 minute interval."
   ::= { sonetVTCurrentEntry 5 }

   sonetVTCurrentUASs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of
        Unavailable Seconds
        encountered by a VT in the current
        15 minute interval."
   ::= { sonetVTCurrentEntry 6 }

   -- the SONET/SDH VT Interval Table

   -- The SONET/SDH VT Interval Table
   -- contains various statistics
   -- collected by each system over a maximum
   -- of the previous 24 hours of
   -- operation.  The past 24 hours may be broken into 96
   -- completed 15 minute intervals.
   -- A system is required to store at
   -- least 4 completed 15 minute interval.
   -- The default value is 32 intervals.

   sonetVTIntervalTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF SonetVTIntervalEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
        "The SONET/SDH VT Interval table."
   ::= { sonetVT 2 }

   sonetVTIntervalEntry OBJECT-TYPE
       SYNTAX  SonetVTIntervalEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
        "An entry in the SONET/SDH VT Interval table."
       INDEX   { ifIndex,

                 sonetVTIntervalNumber }
   ::= { sonetVTIntervalTable 1 }

   SonetVTIntervalEntry ::=
       SEQUENCE {
           sonetVTIntervalNumber     Integer32,
           sonetVTIntervalESs        PerfIntervalCount,
           sonetVTIntervalSESs       PerfIntervalCount,
           sonetVTIntervalCVs        PerfIntervalCount,
           sonetVTIntervalUASs       PerfIntervalCount,
           sonetVTIntervalValidData  TruthValue
       }

   sonetVTIntervalNumber OBJECT-TYPE
       SYNTAX  Integer32 (1..96)
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
         "A number between 1 and 96, which identifies the
         interval for which the set of statistics is available.
         The interval identified by 1 is the most recently
         completed 15 minute interval,
         and the interval identified
         by N is the interval immediately preceding the
         one identified
         by N-1."
   ::= { sonetVTIntervalEntry 1 }

   sonetVTIntervalESs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of
        Errored Seconds encountered
        by a SONET/SDH VT in a particular 15-minute interval
        in the past 24 hours."
   ::= { sonetVTIntervalEntry 2 }

   sonetVTIntervalSESs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of
        Severely Errored Seconds
        encountered by a SONET/SDH VT
        in a particular 15-minute interval

        in the past 24 hours."
   ::= { sonetVTIntervalEntry 3 }

   sonetVTIntervalCVs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of Coding
        Violations encountered by a
        SONET/SDH VT in a particular 15-minute interval
        in the past 24 hours."
   ::= { sonetVTIntervalEntry 4 }

   sonetVTIntervalUASs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
        "The counter associated with the number of
        Unavailable Seconds
        encountered by a VT in a particular 15-minute interval
        in the past 24 hours."
   ::= { sonetVTIntervalEntry 5 }

   sonetVTIntervalValidData OBJECT-TYPE
       SYNTAX  TruthValue
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
          "This variable indicates if the data for this
           interval is valid."
       ::= { sonetVTIntervalEntry 6 }

   -- The SONET/SDH Far End VT group

   -- This group consists of two tables:
   --    SONET/SDH Far End VT Current Table
   --    SONET/SDH Far End VT Interval Table

   -- The SONET/SDH Far End VT Current

   -- The SONET/SDH Far End VT Current table
   -- contains various statistics
   -- being collected for the current 15 minute interval.
   -- The statistics are collected from
   -- the far end block error code
   -- (FEBE) within the G1 byte of the VT Overhead.

   -- The definitions are the same as described for
   -- the near-end information.

   sonetFarEndVTCurrentTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF SonetFarEndVTCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
           "The SONET/SDH Far End VT Current table."
       ::= { sonetFarEndVT 1 }

   sonetFarEndVTCurrentEntry OBJECT-TYPE
       SYNTAX  SonetFarEndVTCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
           "An entry in the SONET/SDH Far End VT Current table."
       INDEX   { ifIndex }
       ::= { sonetFarEndVTCurrentTable 1 }

   SonetFarEndVTCurrentEntry ::=
       SEQUENCE {
           sonetFarEndVTCurrentESs       PerfCurrentCount,
           sonetFarEndVTCurrentSESs      PerfCurrentCount,
           sonetFarEndVTCurrentCVs       PerfCurrentCount,
           sonetFarEndVTCurrentUASs      PerfCurrentCount
       }

   sonetFarEndVTCurrentESs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
           "The counter associated with the number of Far
           End Errored Seconds encountered by a SONET/SDH
           interface in the current 15 minute interval."
   ::= { sonetFarEndVTCurrentEntry 1 }

   sonetFarEndVTCurrentSESs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
           "The counter associated with the number of
           Far End Severely Errored Seconds
           encountered by a SONET/SDH VT interface
           in the current 15 minute
           interval."

       ::= { sonetFarEndVTCurrentEntry 2 }

   sonetFarEndVTCurrentCVs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
           "The counter associated with the number of
           Far End Coding Violations reported via
           the far end block error count
           encountered by a
           SONET/SDH VT interface
           in the current 15 minute interval."
       ::= { sonetFarEndVTCurrentEntry 3 }

   sonetFarEndVTCurrentUASs OBJECT-TYPE
      SYNTAX  PerfCurrentCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
         "The counter associated with the number of
         Far End Unavailable Seconds
         encountered by a
         SONET/SDH VT interface
         in the current 15 minute interval."
      ::= { sonetFarEndVTCurrentEntry 4 }

   -- The SONET/SDH Far End VT Interval Table

   -- The SONET/SDH Far End VT Interval Table
   -- contains various statistics
   -- collected by each system over a maximum
   -- of the previous 24 hours of
   -- operation.  The past 24 hours may be broken into 96
   -- completed 15 minute intervals.
   -- A system is required to store at
   -- least 4 completed 15 minute interval.
   -- The default value is 32 intervals.

   sonetFarEndVTIntervalTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF SonetFarEndVTIntervalEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
          "The SONET/SDH Far End VT Interval table."
       ::= { sonetFarEndVT 2 }

   sonetFarEndVTIntervalEntry OBJECT-TYPE
       SYNTAX  SonetFarEndVTIntervalEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
         "An entry in the SONET/SDH Far
         End VT Interval table."
       INDEX   { ifIndex,
                 sonetFarEndVTIntervalNumber }
       ::= { sonetFarEndVTIntervalTable 1 }

   SonetFarEndVTIntervalEntry ::=
      SEQUENCE {
            sonetFarEndVTIntervalNumber     Integer32,
            sonetFarEndVTIntervalESs        PerfIntervalCount,
            sonetFarEndVTIntervalSESs       PerfIntervalCount,
            sonetFarEndVTIntervalCVs        PerfIntervalCount,
            sonetFarEndVTIntervalUASs       PerfIntervalCount,
            sonetFarEndVTIntervalValidData  TruthValue
       }

   sonetFarEndVTIntervalNumber OBJECT-TYPE
       SYNTAX  Integer32 (1..96)
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
          "A number between 1 and 96, which identifies the
          interval for which the set of statistics is available.
          The interval identified by 1 is the most recently
          completed 15 minute interval,
          and the interval identified
          by N is the interval immediately preceding the
          one identified
          by N-1."
       ::= { sonetFarEndVTIntervalEntry 1 }

   sonetFarEndVTIntervalESs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
             "The counter associated with the number of
             Far End Errored Seconds encountered
             by a SONET/SDH VT interface
             in a particular 15-minute interval
             in the past 24 hours."
      ::= { sonetFarEndVTIntervalEntry 2 }

   sonetFarEndVTIntervalSESs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
             "The counter associated with the number of
             Far End Severely Errored Seconds
             encountered by a SONET/SDH VT interface
             in a particular 15-minute interval
             in the past 24 hours."
       ::= { sonetFarEndVTIntervalEntry 3 }

   sonetFarEndVTIntervalCVs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
            "The counter associated with the number of
            Far End Coding Violations reported via
            the far end block error count
            encountered by a
            SONET/SDH VT interface in a
            particular 15-minute interval
            in the past 24 hours."
       ::= { sonetFarEndVTIntervalEntry 4 }

   sonetFarEndVTIntervalUASs OBJECT-TYPE
      SYNTAX  PerfIntervalCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
          "The counter associated with the number of
          Far End Unavailable Seconds
          encountered by a
          SONET/SDH VT interface in a
          particular 15-minute interval
          in the past 24 hours."
      ::= { sonetFarEndVTIntervalEntry 5 }

   sonetFarEndVTIntervalValidData OBJECT-TYPE
       SYNTAX  TruthValue
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
          "This variable indicates if the data for this
           interval is valid."
       ::= { sonetFarEndVTIntervalEntry 6 }

   -- conformance information

   sonetConformance OBJECT IDENTIFIER ::= { sonetMIB 4 }

   sonetGroups      OBJECT IDENTIFIER ::= { sonetConformance 1 }
   sonetCompliances OBJECT IDENTIFIER ::= { sonetConformance 2 }

   -- deprecated compliance statement

   sonetCompliance MODULE-COMPLIANCE
       STATUS  deprecated
       DESCRIPTION
               "The compliance statement for SONET/SDH interfaces."

       MODULE  -- this module
           MANDATORY-GROUPS { sonetMediumStuff, sonetSectionStuff }

           GROUP       sonetLineStuff
           DESCRIPTION
               "Implementation of this group is mandatory for all
                SONET/SDH systems that terminate SONET/SDH Lines,
                Paths or Virtual Tributaries."

           GROUP       sonetFarEndLineStuff
           DESCRIPTION
               "Implementation of this group is optional for all
                SONET/SDH systems that terminate SONET/SDH Lines,
                Paths or Virtual Tributaries, and that
                provide for a far end block error (FEBE)
                information at the SONET/SDH Line Layer."

           GROUP       sonetPathStuff
           DESCRIPTION
               "Implementation of this group is mandatory for all
                SONET/SDH systems that terminate SONET/SDH
                Paths or Virtual Tributaries."

           OBJECT      sonetPathCurrentWidth
           MIN-ACCESS  read-only
           DESCRIPTION
               "Write access is not required."

           GROUP       sonetFarEndPathStuff
           DESCRIPTION
               "Implementation of this group is optional for all
                SONET/SDH systems that terminate SONET/SDH
                Paths or Virtual Tributaries, and that process
                Far End information."

           GROUP       sonetVTStuff
           DESCRIPTION
               "Implementation of this group is mandatory for all
                SONET/SDH systems that terminate SONET/SDH Virtual
                Tributaries."

           OBJECT      sonetVTCurrentWidth
           MIN-ACCESS  read-only
           DESCRIPTION
               "Write access is not required."

           GROUP       sonetFarEndVTStuff
           DESCRIPTION
               "Implementation of this group is optional for all
                SONET/SDH systems that terminate the SONET/SDH
                floating Virtual Tributaries, and that process
                Far End information."

       ::= { sonetCompliances 1 }

   -- current compliance statements

   sonetCompliance2 MODULE-COMPLIANCE
       STATUS  current
------分隔线----------------------------
顶一下
(0)
0%
踩一下
(0)
0%
------分隔线----------------------------
最新评论 查看所有评论
发表评论 查看所有评论
请自觉遵守互联网相关的政策法规,严禁发布色情、暴力、反动的言论。
评价:
表情:
用户名: 密码: 验证码:
推荐内容