STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the
interval for which the set of statistics is available.
The interval identified by 1 is the most recently
completed 15 minute interval,
and the interval identified
by N is the interval immediately preceding the
one identified
by N-1."
::= { sonetFarEndPathIntervalEntry 1 }
sonetFarEndPathIntervalESs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Far End Errored Seconds encountered
by a SONET/SDH Path interface in a
particular 15-minute interval
in the past 24 hours."
::= { sonetFarEndPathIntervalEntry 2 }
sonetFarEndPathIntervalSESs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Far End Severely Errored Seconds
encountered by a SONET/SDH Path interface
in a particular 15-minute interval
in the past 24 hours."
::= { sonetFarEndPathIntervalEntry 3 }
sonetFarEndPathIntervalCVs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Far End Coding Violations reported via
the far end block error count
encountered by a
SONET/SDH Path interface
in a particular 15-minute interval
in the past 24 hours."
::= { sonetFarEndPathIntervalEntry 4 }
sonetFarEndPathIntervalUASs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Far End Unavailable Seconds
encountered by a
SONET/SDH Path interface in
a particular 15-minute interval
in the past 24 hours."
::= { sonetFarEndPathIntervalEntry 5 }
sonetFarEndPathIntervalValidData OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates if the data for this
interval is valid."
::= { sonetFarEndPathIntervalEntry 6 }
-- the SONET/SDH Virtual Tributary group
-- this group consists of 2 tables:
-- - the SONET/SDH VT Current Table
-- - the SONET/SDH VT Interval Table
-- Corresponding SDH signals for SONET VTs are
-- as follows:
-- A VT1.5 = TU11
-- A VT2 = TU12
-- A VT3 = none
-- none = TU3
-- A VT6 = TU2
-- the SONET/SDH VT Current Table
-- The SONET/SDH VT current table
-- contains various statistics
-- being collected for the
-- current 15 minute interval.
sonetVTCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF SonetVTCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SONET/SDH VT Current table."
::= { sonetVT 1 }
sonetVTCurrentEntry OBJECT-TYPE
SYNTAX SonetVTCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the SONET/SDH VT Current table."
INDEX { ifIndex }
::= { sonetVTCurrentTable 1 }
SonetVTCurrentEntry ::=
SEQUENCE {
sonetVTCurrentWidth INTEGER,
sonetVTCurrentStatus Integer32,
sonetVTCurrentESs PerfCurrentCount,
sonetVTCurrentSESs PerfCurrentCount,
sonetVTCurrentCVs PerfCurrentCount,
sonetVTCurrentUASs PerfCurrentCount
}
sonetVTCurrentWidth OBJECT-TYPE
SYNTAX INTEGER {
vtWidth15VC11(1),
vtWidth2VC12(2),
vtWidth3(3),
vtWidth6VC2(4),
vtWidth6c(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A value that indicates the type of the SONET
VT and SDH VC. Assigned widths are
VT1.5/VC11, VT2/VC12, VT3, VT6/VC2, and VT6c."
::= { sonetVTCurrentEntry 1 }
sonetVTCurrentStatus OBJECT-TYPE
SYNTAX Integer32 (1..126)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the
status of the interface.
The sonetVTCurrentStatus
is a bit map represented
as a sum, therefore,
it can represent multiple defects
and failures
simultaneously.
The sonetVTNoDefect should be
set if and only if
no other flag is set.
The various bit positions are:
1 sonetVTNoDefect
2 sonetVTLOP
4 sonetVTPathAIS
8 sonetVTPathRDI
16 sonetVTPathRFI
32 sonetVTUnequipped
64 sonetVTSignalLabelMismatch"
::= { sonetVTCurrentEntry 2 }
sonetVTCurrentESs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Errored
Seconds encountered by a SONET/SDH
VT in the current 15 minute interval."
::= { sonetVTCurrentEntry 3 }
sonetVTCurrentSESs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Severely Errored Seconds
encountered by a SONET/SDH VT in the current 15 minute
interval."
::= { sonetVTCurrentEntry 4 }
sonetVTCurrentCVs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Coding
Violations encountered by a
SONET/SDH VT in the current 15 minute interval."
::= { sonetVTCurrentEntry 5 }
sonetVTCurrentUASs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Unavailable Seconds
encountered by a VT in the current
15 minute interval."
::= { sonetVTCurrentEntry 6 }
-- the SONET/SDH VT Interval Table
-- The SONET/SDH VT Interval Table
-- contains various statistics
-- collected by each system over a maximum
-- of the previous 24 hours of
-- operation. The past 24 hours may be broken into 96
-- completed 15 minute intervals.
-- A system is required to store at
-- least 4 completed 15 minute interval.
-- The default value is 32 intervals.
sonetVTIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF SonetVTIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SONET/SDH VT Interval table."
::= { sonetVT 2 }
sonetVTIntervalEntry OBJECT-TYPE
SYNTAX SonetVTIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the SONET/SDH VT Interval table."
INDEX { ifIndex,
sonetVTIntervalNumber }
::= { sonetVTIntervalTable 1 }
SonetVTIntervalEntry ::=
SEQUENCE {
sonetVTIntervalNumber Integer32,
sonetVTIntervalESs PerfIntervalCount,
sonetVTIntervalSESs PerfIntervalCount,
sonetVTIntervalCVs PerfIntervalCount,
sonetVTIntervalUASs PerfIntervalCount,
sonetVTIntervalValidData TruthValue
}
sonetVTIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the
interval for which the set of statistics is available.
The interval identified by 1 is the most recently
completed 15 minute interval,
and the interval identified
by N is the interval immediately preceding the
one identified
by N-1."
::= { sonetVTIntervalEntry 1 }
sonetVTIntervalESs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Errored Seconds encountered
by a SONET/SDH VT in a particular 15-minute interval
in the past 24 hours."
::= { sonetVTIntervalEntry 2 }
sonetVTIntervalSESs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Severely Errored Seconds
encountered by a SONET/SDH VT
in a particular 15-minute interval
in the past 24 hours."
::= { sonetVTIntervalEntry 3 }
sonetVTIntervalCVs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Coding
Violations encountered by a
SONET/SDH VT in a particular 15-minute interval
in the past 24 hours."
::= { sonetVTIntervalEntry 4 }
sonetVTIntervalUASs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Unavailable Seconds
encountered by a VT in a particular 15-minute interval
in the past 24 hours."
::= { sonetVTIntervalEntry 5 }
sonetVTIntervalValidData OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates if the data for this
interval is valid."
::= { sonetVTIntervalEntry 6 }
-- The SONET/SDH Far End VT group
-- This group consists of two tables:
-- SONET/SDH Far End VT Current Table
-- SONET/SDH Far End VT Interval Table
-- The SONET/SDH Far End VT Current
-- The SONET/SDH Far End VT Current table
-- contains various statistics
-- being collected for the current 15 minute interval.
-- The statistics are collected from
-- the far end block error code
-- (FEBE) within the G1 byte of the VT Overhead.
-- The definitions are the same as described for
-- the near-end information.
sonetFarEndVTCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF SonetFarEndVTCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SONET/SDH Far End VT Current table."
::= { sonetFarEndVT 1 }
sonetFarEndVTCurrentEntry OBJECT-TYPE
SYNTAX SonetFarEndVTCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the SONET/SDH Far End VT Current table."
INDEX { ifIndex }
::= { sonetFarEndVTCurrentTable 1 }
SonetFarEndVTCurrentEntry ::=
SEQUENCE {
sonetFarEndVTCurrentESs PerfCurrentCount,
sonetFarEndVTCurrentSESs PerfCurrentCount,
sonetFarEndVTCurrentCVs PerfCurrentCount,
sonetFarEndVTCurrentUASs PerfCurrentCount
}
sonetFarEndVTCurrentESs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Far
End Errored Seconds encountered by a SONET/SDH
interface in the current 15 minute interval."
::= { sonetFarEndVTCurrentEntry 1 }
sonetFarEndVTCurrentSESs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Far End Severely Errored Seconds
encountered by a SONET/SDH VT interface
in the current 15 minute
interval."
::= { sonetFarEndVTCurrentEntry 2 }
sonetFarEndVTCurrentCVs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Far End Coding Violations reported via
the far end block error count
encountered by a
SONET/SDH VT interface
in the current 15 minute interval."
::= { sonetFarEndVTCurrentEntry 3 }
sonetFarEndVTCurrentUASs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Far End Unavailable Seconds
encountered by a
SONET/SDH VT interface
in the current 15 minute interval."
::= { sonetFarEndVTCurrentEntry 4 }
-- The SONET/SDH Far End VT Interval Table
-- The SONET/SDH Far End VT Interval Table
-- contains various statistics
-- collected by each system over a maximum
-- of the previous 24 hours of
-- operation. The past 24 hours may be broken into 96
-- completed 15 minute intervals.
-- A system is required to store at
-- least 4 completed 15 minute interval.
-- The default value is 32 intervals.
sonetFarEndVTIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF SonetFarEndVTIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SONET/SDH Far End VT Interval table."
::= { sonetFarEndVT 2 }
sonetFarEndVTIntervalEntry OBJECT-TYPE
SYNTAX SonetFarEndVTIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the SONET/SDH Far
End VT Interval table."
INDEX { ifIndex,
sonetFarEndVTIntervalNumber }
::= { sonetFarEndVTIntervalTable 1 }
SonetFarEndVTIntervalEntry ::=
SEQUENCE {
sonetFarEndVTIntervalNumber Integer32,
sonetFarEndVTIntervalESs PerfIntervalCount,
sonetFarEndVTIntervalSESs PerfIntervalCount,
sonetFarEndVTIntervalCVs PerfIntervalCount,
sonetFarEndVTIntervalUASs PerfIntervalCount,
sonetFarEndVTIntervalValidData TruthValue
}
sonetFarEndVTIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the
interval for which the set of statistics is available.
The interval identified by 1 is the most recently
completed 15 minute interval,
and the interval identified
by N is the interval immediately preceding the
one identified
by N-1."
::= { sonetFarEndVTIntervalEntry 1 }
sonetFarEndVTIntervalESs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Far End Errored Seconds encountered
by a SONET/SDH VT interface
in a particular 15-minute interval
in the past 24 hours."
::= { sonetFarEndVTIntervalEntry 2 }
sonetFarEndVTIntervalSESs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Far End Severely Errored Seconds
encountered by a SONET/SDH VT interface
in a particular 15-minute interval
in the past 24 hours."
::= { sonetFarEndVTIntervalEntry 3 }
sonetFarEndVTIntervalCVs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Far End Coding Violations reported via
the far end block error count
encountered by a
SONET/SDH VT interface in a
particular 15-minute interval
in the past 24 hours."
::= { sonetFarEndVTIntervalEntry 4 }
sonetFarEndVTIntervalUASs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Far End Unavailable Seconds
encountered by a
SONET/SDH VT interface in a
particular 15-minute interval
in the past 24 hours."
::= { sonetFarEndVTIntervalEntry 5 }
sonetFarEndVTIntervalValidData OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates if the data for this
interval is valid."
::= { sonetFarEndVTIntervalEntry 6 }
-- conformance information
sonetConformance OBJECT IDENTIFIER ::= { sonetMIB 4 }
sonetGroups OBJECT IDENTIFIER ::= { sonetConformance 1 }
sonetCompliances OBJECT IDENTIFIER ::= { sonetConformance 2 }
-- deprecated compliance statement
sonetCompliance MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for SONET/SDH interfaces."
MODULE -- this module
MANDATORY-GROUPS { sonetMediumStuff, sonetSectionStuff }
GROUP sonetLineStuff
DESCRIPTION
"Implementation of this group is mandatory for all
SONET/SDH systems that terminate SONET/SDH Lines,
Paths or Virtual Tributaries."
GROUP sonetFarEndLineStuff
DESCRIPTION
"Implementation of this group is optional for all
SONET/SDH systems that terminate SONET/SDH Lines,
Paths or Virtual Tributaries, and that
provide for a far end block error (FEBE)
information at the SONET/SDH Line Layer."
GROUP sonetPathStuff
DESCRIPTION
"Implementation of this group is mandatory for all
SONET/SDH systems that terminate SONET/SDH
Paths or Virtual Tributaries."
OBJECT sonetPathCurrentWidth
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
GROUP sonetFarEndPathStuff
DESCRIPTION
"Implementation of this group is optional for all
SONET/SDH systems that terminate SONET/SDH
Paths or Virtual Tributaries, and that process
Far End information."
GROUP sonetVTStuff
DESCRIPTION
"Implementation of this group is mandatory for all
SONET/SDH systems that terminate SONET/SDH Virtual
Tributaries."
OBJECT sonetVTCurrentWidth
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
GROUP sonetFarEndVTStuff
DESCRIPTION
"Implementation of this group is optional for all
SONET/SDH systems that terminate the SONET/SDH
floating Virtual Tributaries, and that process
Far End information."
::= { sonetCompliances 1 }
-- current compliance statements
sonetCompliance2 MODULE-COMPLIANCE
STATUS current