  Network Working Group                                          A. Berger
Request for Comments: 3621                               PowerDsine Inc.
Category: Standards Track                                   D. Romascanu
                                                                   Avaya
                                                           December 2003

                           Power Ethernet MIB

Status of this Memo

   This document specifies an Internet standards track protocol for the
   Internet community, and requests discussion and suggestions for
   improvements.  Please refer to the current edition of the "Internet
   Official Protocol Standards" (STD 1) for the standardization state
   and status of this protocol.  Distribution of this memo is unlimited.

Copyright Notice

   Copyright (C) The Internet Society (2003).  All Rights Reserved.

Abstract

   This memo defines a portion of the Management Information Base (MIB)
   for use with network management protocols in the Internet community.
   This document proposes an extension to the Ethernet-like Interfaces
   MIB with a set of objects for managing Power Sourcing Equipment
   (PSE).

Table of Contents

   1.  Introduction . . . . . . . . . . . . . . . . . . . . . . . . .  2
   2.  The Internet-Standard Management Framework . . . . . . . . . .  2
   3.  Overview . . . . . . . . . . . . . . . . . . . . . . . . . . .  2
   4.  MIB Structure. . . . . . . . . . . . . . . . . . . . . . . . .  3
   5.  Definitions. . . . . . . . . . . . . . . . . . . . . . . . . .  3
   6.  Acknowledgements . . . . . . . . . . . . . . . . . . . . . . . 16
   7.  References . . . . . . . . . . . . . . . . . . . . . . . . . . 16
       7.1.  Normative References . . . . . . . . . . . . . . . . . . 16
       7.2.  Informative References . . . . . . . . . . . . . . . . . 17
   8.  Intellectual Property Statement. . . . . . . . . . . . . . . . 17
   9.  Security Considerations. . . . . . . . . . . . . . . . . . . . 18
   10. Authors’ Addresses . . . . . . . . . . . . . . . . . . . . . . 19
   11. Full Copyright Statement . . . . . . . . . . . . . . . . . . . 20

1.  Introduction

   This memo defines a portion of the Management Information Base (MIB)
   for use with network management protocols in the Internet community.
   In particular, it defines a set of MIB objects to manage Power
   Ethernet [IEEE-802.3af] Power Sourcing Equipment (PSE).

   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
   "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
   document are to be interpreted as described in [RFC2119].

2.  The Internet-Standard Management Framework

   For a detailed overview of the documents that describe the current
   Internet-Standard Management Framework, please refer to section 7 of
   RFC 3410 [RFC3410].

   Managed objects are accessed via a virtual information store, termed
   the Management Information Base or MIB.  MIB objects are generally
   accessed through the Simple Network Management Protocol (SNMP).
   Objects in the MIB are defined using the mechanisms defined in the
   Structure of Management Information (SMI).  This memo specifies a MIB
   module that is compliant to the SMIv2, which is described in STD 58,
   RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC 2580
   [RFC2580].

3.  Overview

   The emergence of IP telephony as an application that allows voice
   applications to be run over the same infrastructure as data
   applications has led to the emergence of Ethernet IP phones, which
   have similar functions and characteristics as traditional phones.
   Powering the phone with the same cable used for signal transfer is
   one of the functions that are being taken as granted.  The IEEE 802.3
   Working Group has initiated standardization on this subject,
   currently known as the IEEE 802.3af work [IEEE-802.3af].

   The IEEE 802.3af WG did not define a full management interface, but
   only the hardware registers that will allow for management interfaces
   to be built for a powered Ethernet device.  The MIB module defined in
   this document extends the Ethernet-like Interfaces MIB [RFC3635] with
   the management objects required for the management of the powered
   Ethernet devices and ports.

   The following abbreviations are defined in [IEEE-802.3af] and will be
   used with the same significance in this document:

   PSE - Power Sourcing Equipment;

   PD - Powered Device

4.  MIB Structure

   These MIB objects are categorized into three MIB groups.

   The pethPsePortTable defines the objects used for configuring and
   describing the status of ports on a PSE device.  Examples of PSE
   devices are Ethernet switches that support power Ethernet and mid-
   span boxes.

   The pethMainPseObjects MIB group defines the management objects for a
   managed main power source in a PSE device.  Ethernet switches are one
   example of boxes that would support these objects.

   The pethNotificationControlTable includes objects that control the
   transmission of notifications from the agent to a management
   application.

5.  Definitions

POWER-ETHERNET-MIB DEFINITIONS ::= BEGIN

IMPORTS
           MODULE-IDENTITY, mib-2, OBJECT-TYPE, Integer32,
           Gauge32, Counter32, NOTIFICATION-TYPE
                   FROM SNMPv2-SMI
           TruthValue
                   FROM SNMPv2-TC
           MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
                   FROM SNMPv2-CONF

            SnmpAdminString
                    FROM SNMP-FRAMEWORK-MIB;

    powerEthernetMIB MODULE-IDENTITY

         LAST-UPDATED    "200311240000Z"  -- November 24, 2003
         ORGANIZATION "IETF Ethernet Interfaces and Hub MIB
                       Working Group"

         CONTACT-INFO
         "
          WG Charter:
          http://www.ietf.org/html.charters/hubmib-charter.html

         Mailing lists:
          General Discussion: hubmib@ietf.org
          To Subscribe: hubmib-requests@ietf.org
          In Body: subscribe your_email_address

         Chair: Dan Romascanu
          Avaya
          Tel:  +972-3-645-8414
          Email: dromasca@avaya.com

         Editor: Avi Berger
          PowerDsine Inc.
          Tel:    972-9-7755100 Ext 307
          Fax:    972-9-7755120
          E-mail: avib@PowerDsine.com
         "

        DESCRIPTION
              "The MIB module for managing Power Source Equipment
               (PSE) working according to the IEEE 802.af Powered
               Ethernet (DTE Power via MDI) standard.

                The following terms are used throughout this
                MIB module.  For complete formal definitions,
                the IEEE 802.3 standards should be consulted
                wherever possible:

                Group - A recommended, but optional, entity
                defined by the IEEE 802.3 management standard,
                in order to support a modular numbering scheme.
                The classical example allows an implementor to
                represent field-replaceable units as groups of
                ports, with the port numbering matching the
                modular hardware implementation.

              Port - This entity identifies the port within the group
              for which this entry contains information.  The numbering
              scheme for ports is implementation specific.

             Copyright (c) The Internet Society (2003).  This version
             of this MIB module is part of RFC 3621; See the RFC
             itself for full legal notices."

       REVISION    "200311240000Z"  -- November 24, 2003
       DESCRIPTION "Initial version, published as RFC 3621."
       ::= { mib-2 105 }

pethNotifications OBJECT IDENTIFIER ::= { powerEthernetMIB 0 }
pethObjects       OBJECT IDENTIFIER ::= { powerEthernetMIB 1 }
pethConformance   OBJECT IDENTIFIER ::= { powerEthernetMIB 2 }

-- PSE Objects

  pethPsePortTable OBJECT-TYPE
       SYNTAX      SEQUENCE OF PethPsePortEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "A table of objects that display and control the power
            characteristics of power Ethernet ports on a Power Source
            Entity (PSE) device.  This group will be implemented in
            managed power Ethernet switches and mid-span devices.
            Values of all read-write objects in this table are
            persistent at restart/reboot."
       ::= { pethObjects 1 }

   pethPsePortEntry OBJECT-TYPE
       SYNTAX      PethPsePortEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
               "A set of objects that display and control the power
               characteristics of a power Ethernet PSE port."
       INDEX    { pethPsePortGroupIndex , pethPsePortIndex  }
       ::= { pethPsePortTable 1 }

   PethPsePortEntry ::= SEQUENCE {
       pethPsePortGroupIndex
          Integer32,
       pethPsePortIndex
          Integer32,
       pethPsePortAdminEnable
          TruthValue,
       pethPsePortPowerPairsControlAbility
          TruthValue,
       pethPsePortPowerPairs
          INTEGER,
       pethPsePortDetectionStatus
          INTEGER,
       pethPsePortPowerPriority
          INTEGER,

       pethPsePortMPSAbsentCounter
          Counter32,
       pethPsePortType
          SnmpAdminString,
       pethPsePortPowerClassifications
          INTEGER,
       pethPsePortInvalidSignatureCounter
          Counter32,
       pethPsePortPowerDeniedCounter
          Counter32,
       pethPsePortOverLoadCounter
          Counter32,
       pethPsePortShortCounter
          Counter32
  }

     pethPsePortGroupIndex OBJECT-TYPE
       SYNTAX      Integer32 (1..2147483647)
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "This variable uniquely identifies the group
            containing the port to which a power Ethernet PSE is
            connected.  Group means box in the stack, module in a
            rack and the value 1 MUST be used for non-modular devices.
            Furthermore, the same value MUST be used in this variable,
            pethMainPseGroupIndex, and pethNotificationControlGroupIndex
            to refer to a given box in a stack or module in the rack."
       ::= { pethPsePortEntry 1 }

     pethPsePortIndex OBJECT-TYPE
       SYNTAX      Integer32 (1..2147483647)
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "This variable uniquely identifies the power Ethernet PSE
            port within group pethPsePortGroupIndex to which the
            power Ethernet PSE entry is connected."
       ::= { pethPsePortEntry 2 }

     pethPsePortAdminEnable OBJECT-TYPE
    SYNTAX TruthValue
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
        "true (1) An interface which can provide the PSE functions.
         false(2) The interface will act as it would if it had no PSE
         function."

    REFERENCE
      "IEEE Std 802.3af Section 30.9.1.1.2 aPSEAdminState"
    ::= { pethPsePortEntry 3 }

     pethPsePortPowerPairsControlAbility OBJECT-TYPE
    SYNTAX TruthValue
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
        "Describes the capability of controlling the power pairs
         functionality to switch pins for sourcing power.
         The value true indicate that the device has the capability
         to control the power pairs.  When false the PSE Pinout
         Alternative used cannot be controlled through the
         PethPsePortAdminEnable attribute."
    REFERENCE
      "IEEE Std 802.3af Section 30.9.1.1.3
       aPSEPowerPairsControlAbility"
    ::= { pethPsePortEntry 4 }

    pethPsePortPowerPairs OBJECT-TYPE
    SYNTAX INTEGER   {
               signal(1),
               spare(2)
     }
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
        "Describes or controls the pairs in use.  If the value of
         pethPsePortPowerPairsControl is true, this object is
         writable.
         A value of signal(1) means that the signal pairs
         only are in use.
         A value of spare(2) means that the spare pairs
         only are in use."
    REFERENCE
      "IEEE Std 802.3af Section 30.9.1.1.4 aPSEPowerPairs"
    ::= { pethPsePortEntry 5 }

     pethPsePortDetectionStatus OBJECT-TYPE
    SYNTAX INTEGER   {
             disabled(1),
             searching(2),
               deliveringPower(3),
               fault(4),
               test(5),
               otherFault(6)
     }

    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
        "Describes the operational status of the port PD detection.
         A value of disabled(1)- indicates that the PSE State diagram
         is in the state DISABLED.
         A value of deliveringPower(3) - indicates that the PSE State
         diagram is in the state POWER_ON for a duration greater than
         tlim max (see IEEE Std 802.3af Table 33-5 tlim).
         A value of fault(4) - indicates that the PSE State diagram is
         in the state TEST_ERROR.
         A value of test(5) - indicates that the PSE State diagram is
         in the state TEST_MODE.
         A value of otherFault(6) - indicates that the PSE State
         diagram is in the state IDLE due to the variable
         error_conditions.
         A value of searching(2)- indicates the PSE State diagram is
         in a state other than those listed above."
    REFERENCE
      "IEEE Std 802.3af Section 30.9.1.1.5
       aPSEPowerDetectionStatus"
    ::= { pethPsePortEntry 6 }

     pethPsePortPowerPriority OBJECT-TYPE
    SYNTAX INTEGER   {
               critical(1),
               high(2),
               low(3)
     }
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
        "This object controls the priority of the port from the point
         of view of a power management algorithm.  The priority that
         is set by this variable could be used by a control mechanism
         that prevents over current situations by disconnecting first
         ports with lower power priority.  Ports that connect devices
         critical to the operation of the network - like the E911
         telephones ports - should be set to higher priority."
    ::= { pethPsePortEntry 7 }

   pethPsePortMPSAbsentCounter OBJECT-TYPE
    SYNTAX Counter32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
          "This counter is incremented when the PSE state diagram
             transitions directly from the state POWER_ON to the

             state IDLE due to tmpdo_timer_done being asserted."
    REFERENCE
      "IEEE Std 802.3af Section 30.9.1.1.11
       aPSEMPSAbsentCounter"
    ::= { pethPsePortEntry 8 }

   pethPsePortType OBJECT-TYPE
    SYNTAX SnmpAdminString
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
        "A manager will set the value of this variable to indicate
         the type of powered device that is connected to the port.
         The default value supplied by the agent if no value has
         ever been set should be a zero-length octet string."
    ::= { pethPsePortEntry 9 }

    pethPsePortPowerClassifications OBJECT-TYPE
     SYNTAX INTEGER   {
               class0(1),
               class1(2),
               class2(3),
               class3(4),
               class4(5)
     }
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
        "Classification is a way to tag different terminals on the
        Power over LAN network according to their power consumption.
        Devices such as IP telephones, WLAN access points and others,
        will be classified according to their power requirements.

        The meaning of the classification labels is defined in the
        IEEE specification.

       This variable is valid only while a PD is being powered,
        that is, while the attribute pethPsePortDetectionStatus
        is reporting the enumeration deliveringPower."
    REFERENCE
      "IEEE Std 802.3af Section 30.9.1.1.6
       aPSEPowerClassification"
   ::= { pethPsePortEntry 10 }

   pethPsePortInvalidSignatureCounter OBJECT-TYPE
    SYNTAX Counter32
    MAX-ACCESS read-only
    STATUS current

    DESCRIPTION
       "This counter is incremented when the PSE state diagram
         enters the state SIGNATURE_INVALID."
    REFERENCE
          "IEEE Std 802.3af Section 30.9.1.1.7
           aPSEInvalidSignatureCounter"
    ::= { pethPsePortEntry 11 }

   pethPsePortPowerDeniedCounter OBJECT-TYPE
    SYNTAX Counter32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
          "This counter is incremented when the PSE state diagram
             enters the state POWER_DENIED."
    REFERENCE
      "IEEE Std 802.3af Section 30.9.1.1.8
       aPSEPowerDeniedCounter"
    ::= { pethPsePortEntry 12 }

   pethPsePortOverLoadCounter OBJECT-TYPE
    SYNTAX Counter32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
          "This counter is incremented when the PSE state diagram
             enters the state ERROR_DELAY_OVER."
    REFERENCE
      "IEEE Std 802.3af Section 30.9.1.1.9
       aPSEOverLoadCounter"
    ::= { pethPsePortEntry 13 }

   pethPsePortShortCounter OBJECT-TYPE
    SYNTAX Counter32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
          "This counter is incremented when the PSE state diagram
             enters the state ERROR_DELAY_SHORT."
    REFERENCE
      "IEEE Std 802.3af Section 30.9.1.1.10
       aPSEShortCounter"
    ::= { pethPsePortEntry 14 }

-- Main PSE Objects

pethMainPseObjects       OBJECT IDENTIFIER ::= { pethObjects 3 }

pethMainPseTable OBJECT-TYPE
       SYNTAX      SEQUENCE OF PethMainPseEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "A table of objects that display and control attributes
            of the main power source in a PSE  device.  Ethernet
            switches are one example of boxes that would support
            these objects.
            Values of all read-write objects in this table are
            persistent at restart/reboot."
       ::= { pethMainPseObjects 1 }

   pethMainPseEntry OBJECT-TYPE
       SYNTAX      PethMainPseEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
            "A set of objects that display and control the Main
             power of a PSE. "
       INDEX    { pethMainPseGroupIndex }
       ::= { pethMainPseTable 1 }

   PethMainPseEntry ::= SEQUENCE {
       pethMainPseGroupIndex
           Integer32,
       pethMainPsePower
           Gauge32 ,
       pethMainPseOperStatus
           INTEGER,
       pethMainPseConsumptionPower
           Gauge32,
       pethMainPseUsageThreshold
           Integer32
   }
     pethMainPseGroupIndex OBJECT-TYPE
       SYNTAX       Integer32 (1..2147483647)
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "This variable uniquely identifies the group to which
           power Ethernet PSE is connected.  Group means (box in
           the stack, module in a rack) and the value 1 MUST be
           used for non-modular devices.  Furthermore, the same
           value MUST be used in this variable, pethPsePortGroupIndex,
           and pethNotificationControlGroupIndex to refer to a
           given box in a stack or module in a rack."
       ::= { pethMainPseEntry 1 }

     pethMainPsePower OBJECT-TYPE
       SYNTAX      Gauge32  (1..65535)
       UNITS      "Watts"
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The nominal power of the PSE expressed in Watts."
       ::= { pethMainPseEntry 2 }

     pethMainPseOperStatus OBJECT-TYPE
       SYNTAX INTEGER   {
               on(1),
               off(2),
               faulty(3)
          }
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The operational status of the main PSE."
       ::= { pethMainPseEntry 3 }

     pethMainPseConsumptionPower OBJECT-TYPE
       SYNTAX      Gauge32
       UNITS      "Watts"
       MAX-ACCESS  read-only
       STATUS      current