RFC 3877 - Alarm Management Information Base (MIB)(6)

时间:2006-10-31 来源: 作者: 点击:
ituAlarmActiveStatsWarningCurrent, ituAlarmActiveStatsIndeterminates, ituAlarmActiveStatsCriticals, ituAlarmActiveStatsMajors, ituAlarmActiveStatsMinors, ituAlarmActiveStatsWarnings } STATUScurrent D
  
            ituAlarmActiveStatsWarningCurrent,
            ituAlarmActiveStatsIndeterminates,
            ituAlarmActiveStatsCriticals,
            ituAlarmActiveStatsMajors,
            ituAlarmActiveStatsMinors,
            ituAlarmActiveStatsWarnings
             }
     STATUS current
     DESCRIPTION

       "ITU Active Alarm Statistics."
     ::= { ituAlarmGroups 4 }

   END

6.  Examples

6.1.  Alarms Based on linkUp/linkDown Notifications

   This example demonstrates an interface-based alarm that goes into a
   state of "warning" when a linkDown Notification [RFC2863] occurs but
   the ifAdminStatus indicates the interface was taken down
   administratively.  If IfAdminStatus is "up" when the linkDown
   Notification occurs, then there is a problem, so the state of the
   alarm is critical.  A linkUp alarm clears the alarm.

linkDown NOTIFICATION-TYPE
        OBJECTS { ifIndex, ifAdminStatus, ifOperStatus }
        STATUS  current
        DESCRIPTION
            ""
    ::= { snmpTraps 3 }

linkUp NOTIFICATION-TYPE
        OBJECTS { ifIndex, ifAdminStatus, ifOperStatus }
        STATUS  current
        DESCRIPTION
            ""
    ::= { snmpTraps 4 }

 alarmModelIndex                  3
 alarmModelState                  1
 alarmModelNotificationId         linkUp
 alarmModelVarbindIndex           0
 alarmModelVarbindValue           0
 alarmModelDescription            "linkUp"
 alarmModelSpecificPointer        ituAlarmEntry.3.1
 alarmModelVarbindSubtree         ifIndex (1.3.6.1.2.1.2.2.1.1)
 alarmModelResourcePrefix         0.0
 alarmModelRowStatus              active (1)
 ituAlarmEventType                communicationsAlarm (2)
 ituAlarmPerceivedSeverity        cleared (1)
 ituAlarmGenericModel             alarmModelEntry.3.1

 alarmModelIndex                  3
 alarmModelState                  2
 alarmModelNotificationId         linkDown
 alarmModelVarbindIndex           2

 alarmModelVarbindValue           down (2)
 alarmModelDescription            "linkDown administratively"
 alarmModelSpecificPointer        ituAlarmEntry.3.6
 alarmModelVarbindSubtree         ifIndex (1.3.6.1.2.1.2.2.1.1)
 alarmModelResourcePrefix         0.0
 alarmModelRowStatus              active (1)
 ituAlarmEventType                communicationsAlarm (2)
 ituAlarmPerceivedSeverity        warning (6)
 ituAlarmGenericModel             alarmModelEntry.3.2

 alarmModelIndex                  3
 alarmModelState                  3
 alarmModelNotificationId         linkDown
 alarmModelVarbindIndex           2
 alarmModelVarbindValue           up (1)
 alarmModelDescription            "linkDown - confirmed problem"
 alarmModelSpecificPointer        ituAlarmEntry.3.3
 alarmModelVarbindSubtree         ifIndex (1.3.6.1.2.1.2.2.1.1)
 alarmModelResourcePrefix         0.0
 alarmModelRowStatus              active (1)
 ituAlarmEventType                communicationsAlarm (2)
 ituAlarmPerceivedSeverity        critical (3)
 ituAlarmGenericModel             alarmModelEntry.3.3

 alarmActiveIndex                 1
 alarmActiveDateAndTime           2342464573
 alarmActiveDateAndTime           DateAndTime,
 alarmActiveEngineID              SnmpEngineID,
 alarmActiveEngineAddressType     ipV4
 alarmActiveEngineAddress         10.10.10.10
 alarmActiveContextName           SnmpAdminString,
 alarmActiveVariables             3
 alarmActiveNotificationID        1.3.6.1.6.3.1.1.5.3
 alarmActiveResourceId            1.3.6.1.2.1.2.2.1.1.346
 alarmActiveLogPointer            0.0
 alarmActiveModelPointer          alarmModelEntry.3.3
 alarmActiveSpecificPointer       ituAlarmActiveEntry.1.3
 ituAlarmActiveTrendIndication    moreSevere (1)
 ituAlarmDetector                   0.0
 ituAlarmServiceProvider            0.0
 ituAlarmServiceUser                0.0

 alarmActiveVariableIndex                 1
 alarmActiveVariableID                    sysUpTime.0
 alarmActiveVariableValueType             timeTicks(3)
 alarmActiveVariableCounter32Val          0
 alarmActiveVariableUnsigned32Val         0
 alarmActiveVariableTimeTicksVal          46754

 alarmActiveVariableInteger32Val          0
 alarmActiveVariableOctetStringVal        ""
 alarmActiveVariableIpAddressVal          0
 alarmActiveVariableOidVal                0.0
 alarmActiveVariableCounter64Val          0
 alarmActiveVariableIndex                 2
 alarmActiveVariableID                    snmpTrapOID.0
 alarmActiveVariableValueType             objectId(7)
 alarmActiveVariableCounter32Val          0
 alarmActiveVariableUnsigned32Val         0
 alarmActiveVariableTimeTicksVal          0
 alarmActiveVariableInteger32Val          0
 alarmActiveVariableOctetStringVal        ""
 alarmActiveVariableIpAddressVal          0
 alarmActiveVariableOidVal                1.3.6.1.6.3.1.1.5.3
 alarmActiveVariableCounter64Val          0
 alarmActiveVariableIndex                 3
 alarmActiveVariableID                    ifIndex
 alarmActiveVariableValueType             integer32(4)
 alarmActiveVariableCounter32Val          0
 alarmActiveVariableUnsigned32Val         0
 alarmActiveVariableTimeTicksVal          0
 alarmActiveVariableInteger32Val          346
 alarmActiveVariableOctetStringVal        ""
 alarmActiveVariableIpAddressVal          0
 alarmActiveVariableOidVal                0.0
 alarmActiveVariableCounter64Val          0
 alarmActiveVariableIndex                 4
 alarmActiveVariableID                    ifAdminStatus
 alarmActiveVariableValueType             integer32(4)
 alarmActiveVariableCounter32Val          0
 alarmActiveVariableUnsigned32Val         0
 alarmActiveVariableTimeTicksVal          0
 alarmActiveVariableInteger32Val          up (1)
 alarmActiveVariableOctetStringVal        ""
 alarmActiveVariableIpAddressVal          0
 alarmActiveVariableOidVal                0.0
 alarmActiveVariableCounter64Val          0
 alarmActiveVariableIndex                 5
 alarmActiveVariableID                    ifOperStatus
 alarmActiveVariableValueType             integer32(4)
 alarmActiveVariableCounter32Val          0
 alarmActiveVariableUnsigned32Val         0
 alarmActiveVariableTimeTicksVal          0
 alarmActiveVariableInteger32Val          down(2)
 alarmActiveVariableOctetStringVal        ""
 alarmActiveVariableIpAddressVal          0
 alarmActiveVariableOidVal                0.0

 alarmActiveVariableCounter64Val          0
 alarmActiveVariableOpaqueVal

6.2.  Temperature Alarms Using Generic Notifications

   Consider a system able to detect four different temperature states
   for a widget - normal, minor, major, critical.  The system does not
   have any Notification definitions for these alarm states.  A
   temperature alarm can be modelled using the generic alarm
   Notifications of alarmClearState and alarmActive.

alarmModelIndex                  5
alarmModelState                  1
alarmModelNotificationId         alarmClearState
alarmModelVarbindIndex           2
alarmModelVarbindValue           cleared (1)
alarmModelDescription            "Acme Widget Temperature Normal"
alarmModelSpecificPointer        ituAlarmEntry.5.1
alarmModelVarbindSubtree         alarmActiveResourceId
alarmModelResourcePrefix         0.0
alarmModelRowStatus              active (1)
ituAlarmEventType                environmentalAlarm (6)
ituPerceivedSeverity             cleared (1)
ituAlarmGenericModel             alarmModelEntry.5.1

alarmModelIndex                  5
alarmModelState                  2
alarmModelNotificationId         alarmActiveState
alarmModelVarbindIndex           2
alarmModelVarbindValue           minor (5)
alarmModelDescription            "Acme Widget Temperature Minor"
alarmModelSpecificPointer        ituAlarmEntry.5.5
alarmModelVarbindSubtree         alarmActiveResourceId
alarmModelResourcePrefix         0.0
alarmModelRowStatus              active (1)
ituAlarmEventState               environmentalAlarm (6)
ituPerceivedSeverity             minor (5)
ituAlarmGenericModel             alarmModelEntry.5.2

alarmModelIndex                  5
alarmModelState                  3
alarmModelNotificationId         alarmActiveState
alarmModelVarbindIndex           2
alarmModelVarbindValue           major (4)
alarmModelDescription            "Acme Widget Temperature Major"
alarmModelSpecificPointer        ituAlarmEntry.5.4
alarmModelVarbindSubtree         alarmActiveResourceId
alarmModelResourcePrefix         0.0

alarmModelRowStatus              active (1)
ituAlarmEventType                environmentalAlarm (6)
ituPerceivedSeverity             major (4)
ituAlarmGenericModel             alarmModelEntry.5.3
alarmModelIndex                  5
alarmModelState                  4
alarmModelNotificationId         alarmActiveState
alarmModelVarbindIndex           2
alarmModelVarbindValue           critical (3)
alarmModelDescription            "Acme Widget Temperature Critical"
alarmModelSpecificPointer        ituAlarmEntry.5.3
alarmModelVarbindSubtree         alarmActiveResourceId
alarmModelResourcePrefix         0.0
alarmModelRowStatus              active (1)
ituAlarmEventType                environmentalAlarm (6)
ituPerceivedSeverity             critical (3)
ituAlarmGenericModel             alarmModelEntry.5.4

6.3.  Temperature Alarms Without Notifications

   Consider a system able to detect four different temperature states
   for a widget - normal, minor, major, critical.  The system does not
   have any Notification definitions for these alarm states.  A
   temperature alarm can be modelled without specifying any
   Notifications in the alarm model.  When a temperature state other
   than normal is detected, an instance of this alarm would be added to
   the active alarm table, but no Notifications would be sent out.

   This could alternatively be accomplished using the models from
   example 6.2 and by not specifying any target managers in the SNMP-
   TARGET-MIB, which would allow the alarm state Notifications to be
   logged in the Notification Log while still preventing Notifications
   from being transmitted on the wire.

alarmModelIndex                  6
alarmModelState                  1
alarmModelNotificationId         0.0
alarmModelVarbindIndex           0
alarmModelVarbindValue           0
alarmModelDescription            "Widget Temperature"
alarmModelSpecificPointer        ituAlarmEntry.6.1
alarmModelVarbindSubtree         0.0
alarmModelResourcePrefix         0.0
alarmModelRowStatus              active (1)
ituAlarmEventType                environmentalAlarm (6)
ituPerceivedSeverity             cleared (1)
ituAlarmGenericModel             alarmModelEntry.6.1

alarmModelIndex                  6
alarmModelState                  2
alarmModelNotificationId         0.0
alarmModelVarbindIndex           0
alarmModelVarbindValue           0
alarmModelDescription            "Widget Temperature"
alarmModelSpecificPointer        ituAlarmEntry.6.5
alarmModelVarbindSubtree         0.0
alarmModelResourcePrefix         0.0
alarmModelRowStatus              active (1)
ituAlarmEventState               environmentalAlarm (6)
ituAlarmPerceivedSeverity        minor (5)
ituAlarmGenericModel             alarmModelEntry.6.2

alarmModelIndex                  6
alarmModelState                  3
alarmModelNotificationId         0.0
alarmModelVarbindIndex           0
alarmModelVarbindValue           0
alarmModelDescription            "Widget Temperature"
alarmModelSpecificPointer        ituAlarmEntry.6.4
alarmModelVarbindSubtree         0.0
alarmModelResourcePrefix         0.0
alarmModelRowStatus              active (1)
ituAlarmEventType                environmentalAlarm (6)
ituPerceivedSeverity             major (4)
ituAlarmGenericModel             alarmModelEntry.6.3

alarmModelIndex                  6
alarmModelState                  4
alarmModelNotificationId         0.0
alarmModelVarbindIndex           0
alarmModelVarbindValue           0
alarmModelDescription            "Widget Temperature Severe"
alarmModelSpecificPointer        ituAlarmEntry.6.3
alarmModelVarbindSubtree         0.0
alarmModelResourcePrefix         0.0
alarmModelRowStatus              active (1)
ituAlarmEventType                environmentalAlarm (6)
ituPerceivedSeverity             critical (3)
ituAlarmGenericModel             alarmModelEntry.6.4

6.4.  Printer MIB Alarm Example

   Consider the following Notifications defined in the
   printer MIB [RFC3805]:

   prtAlertSeverityLevel OBJECT-TYPE
    -- This value is a type 1 enumeration
    SYNTAX     INTEGER {
                 other(1),
                 critical(3),
                 warning(4)
             }
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
      "The level of severity of this alert table entry.  The printer
      determines the severity level assigned to each entry into the
      table."
    ::= { prtAlertEntry 2 }

   printerV2Alert NOTIFICATION-TYPE
    OBJECTS { prtAlertIndex, prtAlertSeverityLevel, prtAlertGroup,
            prtAlertGroupIndex, prtAlertLocation, prtAlertCode }
    STATUS  current
    DESCRIPTION
      "This trap is sent whenever a critical event is added to the
      prtAlertTable."
    ::= { printerV2AlertPrefix 1 }

   These Notifications can be used to model a printer alarm as follows:

   alarmModelIndex                  9 alarmModelState                  1
   alarmModelNotificationId         alarmClearState
   alarmModelVarbindIndex           0 alarmModelVarbindValue           0
   alarmModelDescription            "Printer Alarm"
   alarmModelSpecificPointer        0.0 alarmModelVarbindSubtree
   prtAlertGroup alarmModelResourcePrefix         0.0
   alarmModelRowStatus              active (1)

   alarmModelIndex                  9 alarmModelState                  2
   alarmModelNotificationId         printerV2Alert
   alarmModelVarbindIndex           2 alarmModelVarbindValue
   warning (4) alarmModelDescription            "Printer Alarm"
   alarmModelSpecificPointer        0.0 alarmModelVarbindSubtree
   prtAlertGroup alarmModelResourcePrefix         0.0
   alarmModelRowStatus              active (1)

   alarmModelIndex                  9 alarmModelState                  3

   alarmModelNotificationId         printerV2Alert
   alarmModelVarbindIndex           2 alarmModelVarbindValue
   other (1) alarmModelDescription            "Printer Alarm - unknown
   severity" alarmModelSpecificPointer        0.0
   alarmModelVarbindSubtree         prtAlertGroup
   alarmModelResourcePrefix         0.0 alarmModelRowStatus
   active (1)

   alarmModelIndex                  9 alarmModelState                  4
   alarmModelNotificationId         printerV2Alert
   alarmModelVarbindIndex           2 alarmModelVarbindValue
   critical (3) alarmModelDescription            "Printer Alarm"
   alarmModelSpecificPointer        0.0 alarmModelVarbindSubtree
   prtAlertGroup alarmModelResourcePrefix         0.0
   alarmModelRowStatus              active (1)

6.5.  RMON Alarm Example

   The RMON MIB [RFC2819] defines a mechanism for generating threshold
   alarms.  When the thresholds are crossed, RisingAlarm and
   FallingAlarm Notifications are generated as appropriate.  These
   Notifications can be used to model an upper threshold alarm as
   follows:

   alarmModelIndex                  6
   alarmModelState                  1
   alarmModelNotificationId         FallingAlarm
   alarmModelVarbindIndex           0
   alarmModelVarbindValue           0
   alarmModelDescription            "RMON Rising Clear Alarm"
   alarmModelSpecificPointer        0.0
   alarmModelVarbindSubtree         alarmIndex
   alarmModelResourcePrefix         0.0
   alarmModelRowStatus              active (1)

   alarmModelIndex                  6
   alarmModelState                  2
   alarmModelNotificationId         RisingAlarm
   alarmModelVarbindIndex           0
   alarmModelVarbindValue           0
   alarmModelDescription            "RMON Rising Alarm"
   alarmModelSpecificPointer        0.0
   alarmModelVarbindSubtree         alarmIndex
   alarmModelResourcePrefix         0.0
   alarmModelRowStatus              active (1)

6.6.  The Lifetime of an Alarm

   The following example demonstrates the relationship between the
   active alarm table, the clear alarm table and the Notification Log
   MIB.

   Consider a system with alarms modelled as in example 1 and which also
   supports the informational Notification dsx3LineStatusChange.

dsx3LineStatusChange NOTIFICATION-TYPE
    OBJECTS { dsx3LineStatus,
              dsx3LineStatusLastChange }
    STATUS  current
    DESCRIPTION
            "A dsx3LineStatusChange trap is sent when the
            value of an instance of dsx3LineStatus changes.  It
            can be utilized by an NMS to trigger polls.  When
            the line status change results in a lower level
            line status change (i.e., ds1), then no traps for
            the lower level are sent."
               ::= { ds3Traps 0 1 }

0. At system start, the active alarm table, alarm clear table and
   the Notification Log are all empty.
         ___________________________     _______________________
        | alarmActiveTable          |   | nlmLogTable           |
        |---------------------------|   |-----------------------|
        | alarmActiveIndex |  alarm |   | nlmLogPointer | notif.|
        |---------------------------|   |-----------------------|
        |___________________________|   |_______________________|

         __________________________________________________
        | alarmClearTable                                  |
        |--------------------------------------------------|
        | alarmClear Index |  alarm                        |
        |--------------------------------------------------|
        |                  |                               |
        |__________________________________________________|

1. Some time later, a link goes down generating a linkDown
   Notification, which is sent out and logged in the
   Notification Log.  As this Notification is modelled as
   an alarm state, an entry is added to the active alarm
   table.
         __________________________________________________
        | alarmActiveTable                                 |
        |--------------------------------------------------|
        | alarmActiveIndex |  alarm                        |
        |--------------------------------------------------|
        |        1         | link down - problem confirmed |
        |__________________________________________________|

         _______________________________________________
        | nlmLogTable                                   |
        |-----------------------------------------------|
        | nlmLogPointer |  Notification                 |
        |-----------------------------------------------|
        |      1        | linkdown                      |
        |_______________________________________________|

         __________________________________________________
        | alarmClearTable                                  |
        |--------------------------------------------------|
        | alarmClear Index |  alarm                        |
        |--------------------------------------------------|
        |                  |                               |
        |__________________________________________________|

2. Some time later, the value of an instance of dsx3LineStatus
   changes.  This Notification is sent out and logged.  As this
   is not modelled into an alarm state, the active alarm table
   remains unchanged.
         __________________________________________________
        | alarmActiveTable                                 |
        |--------------------------------------------------|
        | alarmActiveIndex |  alarm                        |
        |--------------------------------------------------|
        |        1         | linkDown - problem confirmed  |
        |__________________________________________________|

         _____________________________________________
        | nlmLogTable                                 |
        |---------------------------------------------|
        | nlmLogPointer |  Notification               |
        |---------------------------------------------|
        |      1        | linkDown                    |
        |      2        | dsx3LineStatusChange        |