::={lmpTeLinkPerfEntry40} --EndoflmpTeLinkPerfTable --LMPDataLinkTable lmpDataLinkTableOBJECT-TYPE SYNTAXSEQUENCEOFLmpDataLinkEntry MAX-ACCESSnot-accessible STATUScurrent DESCRIPTION "Thistablespecif
  
    ::= { lmpTeLinkPerfEntry 40 }

-- End of lmpTeLinkPerfTable

-- LMP Data Link Table

lmpDataLinkTable OBJECT-TYPE
   SYNTAX        SEQUENCE OF LmpDataLinkEntry
   MAX-ACCESS    not-accessible
   STATUS        current
   DESCRIPTION
       "This table specifies the data-bearing links managed by the
        LMP."
   ::= { lmpObjects 16 }

lmpDataLinkEntry OBJECT-TYPE
   SYNTAX        LmpDataLinkEntry
   MAX-ACCESS    not-accessible
   STATUS        current
   DESCRIPTION
       "An entry in this table exists for each ifEntry that represents
        a data-bearing link.  An ifEntry with an ifIndex must exist
        before the corresponding lmpDataLinkEntry is created.
        If an entry representing the data-bearing link is destroyed in
        the ifTable, then so is the corresponding entry in the
        lmpDataLinkTable.  The administrative status value is
        controlled from the ifEntry.  The index to this table is also
        used to get information in the componentLinkTable

        of the TE-LINK-STD-MIB MIB module."
   INDEX         { ifIndex }
   ::= { lmpDataLinkTable 1 }

LmpDataLinkEntry ::= SEQUENCE {
  lmpDataLinkType               INTEGER,
  lmpDataLinkAddressType        InetAddressType,
  lmpDataLinkIpAddr             InetAddress,
  lmpDataLinkRemoteIpAddress    InetAddress,
  lmpDataLinkRemoteIfId         InterfaceIndexOrZero,
  lmpDataLinkEncodingType       TeLinkEncodingType,
  lmpDataLinkActiveOperStatus   INTEGER,
  lmpDataLinkPassiveOperStatus  INTEGER,
  lmpDataLinkRowStatus          RowStatus,
  lmpDataLinkStorageType        StorageType
}

lmpDataLinkType OBJECT-TYPE
   SYNTAX        INTEGER {
                     port(1),
                     componentLink(2)
                 }
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This attribute specifies whether this data-bearing link is
        a port or a component link.  Component link are multiplex
        capable, whereas ports are not multiplex capable."
   REFERENCE
       "Link Management Protocol, RFC 4204"
   ::= { lmpDataLinkEntry 1 }

lmpDataLinkAddressType OBJECT-TYPE
   SYNTAX        InetAddressType
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This attribute specifies the data-bearing link IP address
        type.  If the data-bearing link is unnumbered, the address
        type must be set to unknown(0)."
   ::= { lmpDataLinkEntry 2 }

lmpDataLinkIpAddr OBJECT-TYPE
   SYNTAX        InetAddress
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "The local Internet address for numbered links.  The type

        of this address is determined by the value of
        lmpDataLinkAddressType object.

        For IPv4 and IPv6 numbered links, this object represents
        the local IP address associated with the data-bearing
        link.  For an unnumbered link, the local address is
        of type unknown and this object is set to the zero-length
        string and the ifIndex object then identifies the
        unnumbered address."
   ::= { lmpDataLinkEntry 3 }

lmpDataLinkRemoteIpAddress OBJECT-TYPE
   SYNTAX        InetAddress
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "The remote Internet address for numbered data-bearing links.
        The type of this address is determined by the
        lmpDataLinkAddressType object.

        For IPv4 and IPv6 numbered links, this object represents the
        remote IP address associated with the data-bearing link.  For
        an unnumbered link, the remote address is of type unknown
        and this object is set to the zero-length string and the
        lmpDataLinkRemoteIfId object then identifies the unnumbered
        address.

        This information is either configured manually or
        communicated by the remote node during the link verification
        procedure."
   ::= { lmpDataLinkEntry 4 }

lmpDataLinkRemoteIfId OBJECT-TYPE
   SYNTAX        InterfaceIndexOrZero
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "Interface identifier of the remote end point.  This
        information is either configured manually or
        communicated by the remote node during the link verification
        procedure."
   ::= { lmpDataLinkEntry 5 }

lmpDataLinkEncodingType OBJECT-TYPE
   SYNTAX        TeLinkEncodingType
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION

       "The encoding type of the data-bearing link."
   REFERENCE
       "Generalized MPLS Signaling Functional Description, RFC 3471"
   ::= { lmpDataLinkEntry 6 }

lmpDataLinkActiveOperStatus OBJECT-TYPE
   SYNTAX        INTEGER {
                     upAlloc(1),
                     upFree(2),
                     down(3),
                     testing(4) }
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "The actual operational status of this data-bearing link
        (active FSM)."
   REFERENCE
       "Link Management Protocol, RFC 4204"
   ::= { lmpDataLinkEntry 7 }

lmpDataLinkPassiveOperStatus OBJECT-TYPE
   SYNTAX        INTEGER {
                     upAlloc(1),
                     upFree(2),
                     down(3),
                     psvTst(4) }
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "The actual operational status of this data-bearing link
        (passive FSM)."
   REFERENCE
       "Link Management Protocol, RFC 4204"
   ::= { lmpDataLinkEntry 8 }

lmpDataLinkRowStatus OBJECT-TYPE
   SYNTAX        RowStatus
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "This variable is used to create, modify, and/or
        delete a row in this table.  None of the writable objects
        in a row can be changed if the status is active(1).
        All read-create objects must have valid and consistent
        values before the row can be activated."
   ::= { lmpDataLinkEntry 9 }

lmpDataLinkStorageType OBJECT-TYPE

   SYNTAX        StorageType
   MAX-ACCESS    read-create
   STATUS        current
   DESCRIPTION
       "The storage type for this conceptual row in the
        lmpDataLinkTable.  Conceptual rows having the value
        ’permanent’ need not allow write-access to any
        columnar object in the row."
   DEFVAL        { nonVolatile }
   ::= { lmpDataLinkEntry 10 }

-- End of lmpDataLinkTable

-- LMP Data Link Performance Table

lmpDataLinkPerfTable OBJECT-TYPE
   SYNTAX        SEQUENCE OF LmpDataLinkPerfEntry
   MAX-ACCESS    not-accessible
   STATUS        current
   DESCRIPTION
       "This table specifies the data-bearing links LMP performance
        counters."
   ::= { lmpObjects 17 }

lmpDataLinkPerfEntry OBJECT-TYPE
   SYNTAX        LmpDataLinkPerfEntry
   MAX-ACCESS    not-accessible
   STATUS        current
   DESCRIPTION
       "An entry in this table contains information about
        the LMP performance counters for the data-bearing links.
        lmpDataLinkDiscontinuityTime is used to indicate potential
        discontinuity for all counter objects in this table."
   INDEX         { ifIndex }
   ::= { lmpDataLinkPerfTable 1 }

LmpDataLinkPerfEntry ::= SEQUENCE {
  lmpDataLinkTestReceived        Counter32,
  lmpDataLinkTestSent            Counter32,
  lmpDataLinkActiveTestSuccess   Counter32,
  lmpDataLinkActiveTestFailure   Counter32,
  lmpDataLinkPassiveTestSuccess  Counter32,
  lmpDataLinkPassiveTestFailure  Counter32,
  lmpDataLinkDiscontinuityTime   TimeStamp
}

lmpDataLinkTestReceived OBJECT-TYPE

   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of Test messages that have
        been received on this data-bearing link."
   ::= { lmpDataLinkPerfEntry 1 }

lmpDataLinkTestSent OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of Test messages that have
        been sent on this data-bearing link."
   ::= { lmpDataLinkPerfEntry 2 }

lmpDataLinkActiveTestSuccess OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of data-bearing link tests
        that were successful on the active side of this data-
        bearing link."
   ::= { lmpDataLinkPerfEntry 3 }

lmpDataLinkActiveTestFailure OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of data-bearing link tests
        that failed on the active side of this data-bearing link."
   ::= { lmpDataLinkPerfEntry 4 }

lmpDataLinkPassiveTestSuccess OBJECT-TYPE
   SYNTAX        Counter32
   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of data-bearing link tests
        that were successful on the passive side of this data-
        bearing link."
   ::= { lmpDataLinkPerfEntry 5 }

lmpDataLinkPassiveTestFailure OBJECT-TYPE
   SYNTAX        Counter32

   MAX-ACCESS    read-only
   STATUS        current
   DESCRIPTION
       "This object counts the number of data-bearing link tests
        that failed on the passive side of this data-bearing link."
   ::= { lmpDataLinkPerfEntry 6 }

lmpDataLinkDiscontinuityTime OBJECT-TYPE
    SYNTAX       TimeStamp
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        "The value of sysUpTime on the most recent occasion at which
         any one or more of this data-bearing link’s counters suffered
         a discontinuity.  The relevant counters are the specific
         instances associated with this data-bearing link of any
         Counter32 object contained in the lmpDataLinkPerfTable.  If
         no such discontinuities have occurred since the last re-
         initialization of the local management subsystem, then this
         object contains a zero value."
    ::= { lmpDataLinkPerfEntry 7 }

-- End of lmpDataLinkPerfTable

-- Notification Configuration

lmpNotificationMaxRate OBJECT-TYPE
   SYNTAX       Unsigned32
   MAX-ACCESS   read-write
   STATUS       current
   DESCRIPTION
       "The LMP notification rate depends on the size of the network,
        the type of links, the network configuration, the
        reliability of the network, etc.

        When designing this MIB, care has been taken to minimize the
        amount of notifications generated for LMP purposes.  Wherever
        possible, notifications are state driven, meaning the
        notifications are sent only when the system changes state.
        The only notifications that are repeated and could cause a
        problem as far as congestion is concerned are the ones
        associated with data link verification.
        Without any considerations to handling of these
        notifications, a problem may arise if the number of data
        links is high.  Since the data link verification notifications
        can happen only once per data link per link verification
        interval, the notification rate should be sustainable if one

        chooses an appropriate link verification interval for a given
        network configuration.  For instance, a network of 100 nodes
        with 5 links of 128 wavelengths each and a link verification
        of 1 minute with no more than 10% of the links failed at any
        given time would have 1 notification per second sent from
        each node, or 100 notifications per second for the whole
        network.  The rest of the notifications are negligible
        compared to this number.

        To alleviate the congestion problem, the
        lmpNotificationMaxRate object can be used to implement a
        throttling mechanism.  It is also possible to enable/disable
        certain type of notifications.

        This variable indicates the maximum number of
        notifications issued per minute.  If events occur
        more rapidly, the implementation may simply fail to
        emit these notifications during that period, or may
        queue them until an appropriate time.  A value of 0
        means no throttling is applied and events may be
        notified at the rate at which they occur.
        Implementations should save the value of this object in
        persistent memory so that it survives restarts or reboot."
   ::= { lmpObjects 18 }

lmpLinkPropertyNotificationsEnabled OBJECT-TYPE
   SYNTAX        TruthValue
   MAX-ACCESS    read-write
   STATUS        current
   DESCRIPTION
       "If this object is true, then it enables the
        generation of lmpTeLinkPropertyMismatch
        and lmpDataLinkPropertyMismatch notifications,
        otherwise these notifications are not emitted.
        Implementations should save the value of this object in
        persistent memory so that it survives restarts or reboot."
   DEFVAL        { false }
   ::= { lmpObjects 19 }

lmpUnprotectedNotificationsEnabled OBJECT-TYPE
   SYNTAX        TruthValue
   MAX-ACCESS    read-write
   STATUS        current
   DESCRIPTION
       "If this object is true, then it enables the
        generation of lmpUnprotected notifications,
        otherwise these notifications are not emitted.
        Implementations should save the value of this object in

        persistent memory so that it survives restarts or reboot."
   DEFVAL        { false }
   ::= { lmpObjects 20 }

lmpCcUpDownNotificationsEnabled OBJECT-TYPE
   SYNTAX        TruthValue
   MAX-ACCESS    read-write
   STATUS        current
   DESCRIPTION
       "If this object is true, then it enables the generation of
        lmpControlChannelUp and lmpControlChannelDown notifications,
        otherwise these notifications are not emitted.
        Implementations should save the value of this object in
        persistent memory so that it survives restarts or reboot."
   DEFVAL        { false }
   ::= { lmpObjects 21 }

lmpTeLinkNotificationsEnabled OBJECT-TYPE
   SYNTAX        TruthValue
   MAX-ACCESS    read-write
   STATUS        current
   DESCRIPTION
       "If this object is true, then it enables the
        generation of lmpTeLinkDegraded and lmpTeLinkNotDegraded
        notifications, otherwise these notifications are not emitted.
        Implementations should save the value of this object in
        persistent memory so that it survives restarts or reboot."
   DEFVAL        { false }
   ::= { lmpObjects 22 }

lmpDataLinkNotificationsEnabled OBJECT-TYPE
   SYNTAX        TruthValue
   MAX-ACCESS    read-write
   STATUS        current
   DESCRIPTION
       "If this object is true, then it enables the
        generation of lmpDataLinkVerificationFailure
        notification, otherwise these notifications are not emitted.
        Implementations should save the value of this object in
        persistent memory so that it survives restarts or reboot."
   DEFVAL        { false }
   ::= { lmpObjects 23 }

-- Notifications

-- Link Property Mismatch Notifications

lmpTeLinkPropertyMismatch NOTIFICATION-TYPE
   OBJECTS       { teLinkRemoteIpAddr,
                   teLinkIncomingIfId }
   STATUS        current
   DESCRIPTION
       "This notification is generated when a TE link property
        mismatch is detected on the node.  The received remote TE link
        ID of the misconfigured TE link is represented by either
        teLinkRemoteIpAddr or teLinkIncomingIfId depending on whether
        the TE link is numbered or unnumbered.  This notification
        should not be sent unless lmpLinkPropertyNotificationsEnabled
        is true.  It is recommended that this notification be reported
        only the first time a mismatch is detected.  Otherwise, for a
        given TE link, this notification can occur no more than once
        per verification interval (lmpGlobalLinkVerificationInterval)."
   ::= { lmpNotifications 1 }

lmpDataLinkPropertyMismatch NOTIFICATION-TYPE
   OBJECTS       { lmpDataLinkType, lmpDataLinkRemoteIfId }
   STATUS        current
   DESCRIPTION
       "This notification is generated when a data-bearing link
        property mismatch is detected on the node.  lmpDataLinkType
        is used to identify the local identifiers associated with
        the data link (the data link interface index can be used
        to determine the TE link interface index as this
        relationship is captured in the interface stack table).
        The remote entity interface ID is the remote entity
        interface ID received in the LinkSummary message.
        This notification should not be sent unless
        lmpLinkPropertyNotificationsEnabled is true.  It is
        recommended that this notification be reported only the
        first time a mismatch is detected.  Otherwise, for a given
        data link, this notification can occur no more than once
        per verification interval (lmpGlobalLinkVerificationInterval)."
   ::= { lmpNotifications 2 }

-- Neighbor Notification

lmpUnprotected NOTIFICATION-TYPE
   OBJECTS       { lmpCcNbrNodeId }
   STATUS        current
   DESCRIPTION
       "This notification is generated when there are more than one
        control channels between LMP neighbors and the last redundant
        control channel has failed.  If the remaining operational
        control channel fails, then there will be no more control
        channels between the pair of nodes and all the TE links

        between the pair of nodes will go to degraded state.  This
        notification should not be sent unless
        lmpUnprotectedNotificationsEnabled is set to true."
   ::= { lmpNotifications 3 }

-- Control Channel Notifications

lmpControlChannelUp NOTIFICATION-TYPE
   OBJECTS       { lmpCcAdminStatus, lmpCcOperStatus }
   STATUS        current
   DESCRIPTION
       "This notification is generated when a control
        channel transitions to the up operational state.  This
        notification should not be sent unless
        lmpCcUpDownNotificationsEnabled is true."
   ::= { lmpNotifications 4 }

lmpControlChannelDown NOTIFICATION-TYPE
   OBJECTS       { lmpCcAdminStatus, lmpCcOperStatus }
   STATUS        current
   DESCRIPTION
       "This notification is generated when a control channel
        transitions out of the up operational state.  This
        notification should not be sent unless
        lmpCcUpDownNotificationsEnabled is true."
   ::= { lmpNotifications 5 }

-- TE Link Notification

lmpTeLinkDegraded NOTIFICATION-TYPE
   OBJECTS       { lmpTeLinkOperStatus }
   STATUS        current
   DESCRIPTION
       "This notification is generated when a lmpTeLinkOperStatus
        object for a TE link enters the degraded state.  This
        notification should not be sent unless
        lmpTeLinkNotificationsEnabled is true."
   ::= { lmpNotifications 6 }

lmpTeLinkNotDegraded NOTIFICATION-TYPE
   OBJECTS       { lmpTeLinkOperStatus }
   STATUS        current
   DESCRIPTION
       "This notification is generated when a lmpTeLinkOperStatus
        object for a TE link leaves the degraded state.  This
        notification should not be sent unless
        lmpTeLinkNotificationsEnabled is true."
   ::= { lmpNotifications 7 }

-- Data-bearing Link Notification

lmpDataLinkVerificationFailure NOTIFICATION-TYPE
   OBJECTS       { lmpDataLinkActiveOperStatus,
                   lmpDataLinkPassiveOperStatus }
   STATUS        current
   DESCRIPTION
       "This notification is generated when a data-bearing
        link verification fails.  This notification should not be sent
        unless lmpDataLinkNotificationsEnabled is true.  For a given
        data link, this notification can occur no more than once per
        verification interval (lmpGlobalLinkVerificationInterval)."
   ::= { lmpNotifications 8 }

-- End of notifications

-- Module compliance

lmpCompliances
   OBJECT IDENTIFIER ::= { lmpConformance 1 }

lmpGroups
   OBJECT IDENTIFIER ::= { lmpConformance 2 }

lmpModuleFullCompliance MODULE-COMPLIANCE
   STATUS current
   DESCRIPTION
       "Compliance statement for agents that support the
        configuration and monitoring of LMP MIB."
   MODULE -- this module

      MANDATORY-GROUPS    { lmpNodeGroup,
                            lmpControlChannelGroup,
                            lmpLinkPropertyCorrelationGroup,
                            lmpPerfGroup,
                            lmpTeLinkGroup,
                            lmpDataLinkGroup }

      GROUP lmpCcIsNotInterfaceGroup
      DESCRIPTION
          "This group is mandatory for devices that support
           control channels that are not interfaces, in addition to
           lmpControlChannelGroup.  The following constraints apply:
           lmpCcIsIf must at least be read-only returning false(1)."

      GROUP lmpCcIsInterfaceGroup
      DESCRIPTION

          "This group is mandatory for devices that support
           control channels that are interfaces, in addition to
           lmpControlChannelGroup.  The following constraints apply:
           lmpCcIsIf must at least be read-only returning true(2)."

      GROUP lmpLinkVerificationGroup
      DESCRIPTION
          "This group is mandatory for devices that support
           the link verification procedure."

      GROUP lmpNotificationGroup
      DESCRIPTION
          "This group is optional."

      -- lmpNbrTable

      OBJECT      lmpNbrRowStatus
      SYNTAX      RowStatus { active(1), notInService(2) }
      WRITE-SYNTAX RowStatus { active(1), notInService(2),
                               createAndGo(4), destroy(6) }
      DESCRIPTION
          "Support for notReady(3) and createAndWait(5) is